Idex Micropump I-Drive IMS Installation, Operation And Warranty Information Download Page 3

DOC No: 7936 REV 

D

STANDARD LIMITED WARRANTY 

 

The products manufactured by Micropump Incorporated are warranted to be free 

from defects in workmanship and material at the time of shipment from the place of 

manufacture.  Micropump will repair or replace, at its option, any part or component which 

fails to conform to this warranty for a period of one year.  Micropump’s obligation under 

this warranty is limited to the repairs or replacement of defective equipment returned to 

Micropump on an F.O.B. destination and freight-prepaid basis.  All normal wear and tear 

is excepted, and product is subject to examination at Micropump to verify that the parts or 

components were defective at the time of sale.

For the purposes of the limited warranties, the “Stator/Controller Assembly” means 

only the stator and the printed circuit board and electronic components contained in 

the controller housing, plus the connecting control and power cables.  The “Power 

Supply Assembly” means only the printed circuit board and the electronic or mechanical 

components located inside or on the power supply enclosure and the “Pump head 

Assembly” means all other parts of the product, including but not limited to, the rotor.

No warranty of any kind is made or shall be imposed with respect to any pump or parts 

(1) that have not been properly installed and tested in operation, (2) that have been 

subject to misuse, negligence, acts of God or the elements, or any other form of casualty, 

or (3) that have been repaired or altered outside Micropump’s facility in a way, so as, in 

our judgment, to affect performance or reliability.

The parties agree that the buyer’s sole and exclusive remedy against Micropump shall 

be for repair or replacement of defective parts under the conditions stated above.  The 

buyer agrees that no other remedy (including but not limited to incidental or consequential 

damages for lost profits, lost sales, loss of use, injury to person or property, or any other 

incidental or consequential loss) shall be available to them.

This warranty shall not apply to prototype pumps, experimental pumps, or brush-type 

electric motors.  Warranty of equipment or accessories from outside sources, purchased 

by Micropump and incorporated into Micropump’s product is subject to the manufacturer’s 

standard warranty, unless specifically agreed otherwise between Micropump and buyer.  

A copy of the warranty on the aforementioned equipment is available on request.

The adjustment or replacement of defective parts made under this warranty will not 
extend the original warranty period.

THE WARRANTY DESCRIBED ABOVE IS THE EXCLUSIVE 

MICROPUMP WARRANTY AND IS IN LIEU OF ALL OTHER 

WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY 

WARRANTY OF MERCHANTABILITY OR FITNESS FOR A 

PARTICULAR PURPOSE OR ANY WARRANTY PREVIOUSLY 

ISSUED.  WE NEITHER ASSUME NOR AUTHORIZE ANY PERSON 

TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION 

WITH THE SALE OR USE OF OUR EQUIPMENT.

Summary of Contents for Micropump I-Drive IMS

Page 1: ...DOC No 7936 REV D INSTALLATION OPERATION AND WARRANTY INFORMATION I Drive...

Page 2: ...in this certi cate must not be put into service until the machinery in which it is incorporated has been declared in conformity with the provisions of the Machinery Directive and their amendments PUBL...

Page 3: ...been subject to misuse negligence acts of God or the elements or any other form of casualty or 3 that have been repaired or altered outside Micropump s facility in a way so as in our judgment to affec...

Page 4: ...s provided with your specific pump General information is given on installation within a system but reference should always be made to instructions provided with ancillary equipment when installing th...

Page 5: ...ity 9 Electrical Connection 10 Lead Assignments 12 Operation 13 Manual Control Adjustment 14 Magnet Decoupling 15 Maintenance 15 Fault Isolation 16 Technical Specification 17 19 Notes 20 22 Table of C...

Page 6: ...Corrosive Liquids Corrosive liquids may eventually produce leak paths around the sealing surfaces of the product The product should be inspected for leaks on a regular basis Flooding and Water Immers...

Page 7: ...feedback The tachometer output has 2 pulses per revolution The output frequency is multiplied by 30 to obtain RPM The main input power is 24 VDC from a class 2 SELV source There are two I Drive model...

Page 8: ...rive motor are supplied separately they will need to be assembled prior to the installation Insert the sealing o ring 1 into the groove in the face of the I Drive 3 Align the adaptor flange 2 so that...

Page 9: ...insert the bulkhead o ring 1 into the groove in the face of the I Drive 3 Position the adaptor flange 2 through the bulkhead hole so that it does not interfere with the sealing of the bulkhead hole S...

Page 10: ...l connections use a common earth ground to avoid hazardous ground loops Ensure that only power supplies having SELV specification are connected to the I Drive CAUTION Ensure that all associated equipm...

Page 11: ...ield bare wire which is a capacitive coupling 220nF 63V with the common black wire If the black lead is connected to the shield EMC will not be affected This can be done at the customer input end of t...

Page 12: ...VDC or 4 20mA potentiometer 4 Tachometer Out Green 5 V square wave 2 pulses per revolution 5 FWD REV Orange Forward float and insulate Reverse ground 6 Shield Connected to housing I Drive Lead Wire As...

Page 13: ...should prime if it has not already been filled with fluid If the pump fails to prime stop the pump and fill the pump head with liquid Shut down Procedure Switch off the I Drive by first setting the e...

Page 14: ...stment of an internal potentiometer To adjust the speed set point 1 Remove and retain the M3 cover screw 1 using a small screwdriver 2 Remove and retain the screw seal 2 3 Insert a small screwdriver 3...

Page 15: ...s must be properly decontaminated by suitably qualified personnel The Material Safety Data Sheet for the pumped liquid must be referred to for correct procedures and precautions to be followed when ha...

Page 16: ...roduct CYCLIC NOISE OR VIBRATIONS Cause Remedy Loose motor mounting bolts Tighten motor mounting bolts Foundation not rigid Relocate motor Pump loose on motor Tighten pump mounting bolts Pump is worn...

Page 17: ...nt 6000 rpm Speed Rated Torque 3500 rpm 56 mNm 8 oz in Input Voltage Range 14 to 30 VDC Max Full Load Current Nominal Voltage 25 C Ambient 1 8A 24 VDC Speed Control 0 to 5 VDC 4 to 20mA Manual Tachome...

Page 18: ...m 106 mNm 15 oz in Input Voltage Range 14 to 30 VDC Max Full Load Current Nominal Voltage 25 C Ambient 2 9A 24 VDC Speed Control 0 to 5 VDC 4 to 20mA Manual Tachometer Out 0 to 5 VDC square wave 2 pul...

Page 19: ...19 DOC No 7936 REV D 85 5 3 37 55 2 17 50 8 2 00 40 8 1 61 5 20 77 9 3 07 44 5 1 75 126 4 4 97 61 9 2 44 4 7 19 Model IMS Mounting Bracket Model IEG Mounting Bracket...