DOC No: 7936 REV
D
1
2
3
5
4
6
1
2
3
5
4
6
MODEL IMS
MODEL IEG
Lead
Function
Color
0-5 VDC
4-20mA Control
Manual Control
1
Power In
Red
+24 VDC, Class 2 (SELV)
2
Common
Black
Isolated from motor housing
3
Control Signal In
White
0-5 VDC or 4-20mA
potentiometer
4
Tachometer Out
Green
5 V square wave-2 pulses per revolution
5
FWD/REV
Orange
Forward (float and insulate), Reverse
(ground)
6
Shield
--
Connected to housing
I-Drive Lead Wire Assignments
The 0-5 VDC Control Signal In is protected to withstand -30 to +30 V applied
to it. Above 6 V and below 0 V the impedance is greater than or equal to 10
kOhm. Within the 0-6 V input range, the input impedance is 30.6 kOhm.
NOTE