background image

DOC No: 7936 REV 

D

The drive enclosure is rated to IP55.  The enclosure rating is maintained 

by using the manual control cover screw and seal.  After adjustment, 

these components must be replaced and secured to the proper torque 

in order to maintain the enclosure rating and protection of internal drive 

controller.

Manual Control Adjustment

Manual Control Adjustment
If your drive is equipped with the manual control option, the speed of the drive is 

controlled by local adjustment of an internal potentiometer.  To adjust the speed set point:

1.  Remove and retain the M3 cover screw (1) using a small screwdriver.  

2.  Remove and retain the screw seal (2).  

3.  Insert a small screwdriver (3) into the access hole and engage the potentiometer 

adjustment screw.  To increase speed, rotate the adjustment clock-wise.  To decrease 

speed, rotate the adjustment counter-clockwise.  The potentiometer is equipped with 

a slip coupling which will allow the user to continue to turn the adjustment screw after 

maximum and minimum speed is reached.  

4.  When adjustment is complete, replace the screw seal (2) and (1) the cover screw.  

Tighten the cover screw to 6 in-lb (678 mNm).

CAUTION

1

2

3

Summary of Contents for Micropump I-Drive IMS

Page 1: ...DOC No 7936 REV D INSTALLATION OPERATION AND WARRANTY INFORMATION I Drive...

Page 2: ...in this certi cate must not be put into service until the machinery in which it is incorporated has been declared in conformity with the provisions of the Machinery Directive and their amendments PUBL...

Page 3: ...been subject to misuse negligence acts of God or the elements or any other form of casualty or 3 that have been repaired or altered outside Micropump s facility in a way so as in our judgment to affec...

Page 4: ...s provided with your specific pump General information is given on installation within a system but reference should always be made to instructions provided with ancillary equipment when installing th...

Page 5: ...ity 9 Electrical Connection 10 Lead Assignments 12 Operation 13 Manual Control Adjustment 14 Magnet Decoupling 15 Maintenance 15 Fault Isolation 16 Technical Specification 17 19 Notes 20 22 Table of C...

Page 6: ...Corrosive Liquids Corrosive liquids may eventually produce leak paths around the sealing surfaces of the product The product should be inspected for leaks on a regular basis Flooding and Water Immers...

Page 7: ...feedback The tachometer output has 2 pulses per revolution The output frequency is multiplied by 30 to obtain RPM The main input power is 24 VDC from a class 2 SELV source There are two I Drive model...

Page 8: ...rive motor are supplied separately they will need to be assembled prior to the installation Insert the sealing o ring 1 into the groove in the face of the I Drive 3 Align the adaptor flange 2 so that...

Page 9: ...insert the bulkhead o ring 1 into the groove in the face of the I Drive 3 Position the adaptor flange 2 through the bulkhead hole so that it does not interfere with the sealing of the bulkhead hole S...

Page 10: ...l connections use a common earth ground to avoid hazardous ground loops Ensure that only power supplies having SELV specification are connected to the I Drive CAUTION Ensure that all associated equipm...

Page 11: ...ield bare wire which is a capacitive coupling 220nF 63V with the common black wire If the black lead is connected to the shield EMC will not be affected This can be done at the customer input end of t...

Page 12: ...VDC or 4 20mA potentiometer 4 Tachometer Out Green 5 V square wave 2 pulses per revolution 5 FWD REV Orange Forward float and insulate Reverse ground 6 Shield Connected to housing I Drive Lead Wire As...

Page 13: ...should prime if it has not already been filled with fluid If the pump fails to prime stop the pump and fill the pump head with liquid Shut down Procedure Switch off the I Drive by first setting the e...

Page 14: ...stment of an internal potentiometer To adjust the speed set point 1 Remove and retain the M3 cover screw 1 using a small screwdriver 2 Remove and retain the screw seal 2 3 Insert a small screwdriver 3...

Page 15: ...s must be properly decontaminated by suitably qualified personnel The Material Safety Data Sheet for the pumped liquid must be referred to for correct procedures and precautions to be followed when ha...

Page 16: ...roduct CYCLIC NOISE OR VIBRATIONS Cause Remedy Loose motor mounting bolts Tighten motor mounting bolts Foundation not rigid Relocate motor Pump loose on motor Tighten pump mounting bolts Pump is worn...

Page 17: ...nt 6000 rpm Speed Rated Torque 3500 rpm 56 mNm 8 oz in Input Voltage Range 14 to 30 VDC Max Full Load Current Nominal Voltage 25 C Ambient 1 8A 24 VDC Speed Control 0 to 5 VDC 4 to 20mA Manual Tachome...

Page 18: ...m 106 mNm 15 oz in Input Voltage Range 14 to 30 VDC Max Full Load Current Nominal Voltage 25 C Ambient 2 9A 24 VDC Speed Control 0 to 5 VDC 4 to 20mA Manual Tachometer Out 0 to 5 VDC square wave 2 pul...

Page 19: ...19 DOC No 7936 REV D 85 5 3 37 55 2 17 50 8 2 00 40 8 1 61 5 20 77 9 3 07 44 5 1 75 126 4 4 97 61 9 2 44 4 7 19 Model IMS Mounting Bracket Model IEG Mounting Bracket...

Page 20: ...20 DOC No 7936 REV D Notes...

Page 21: ...E mail info micropump idexcorp com Web www micropump com To purchase pumps parts or receive further information contact your local Micropump distributor or contact Micropump directly NO 3798 MICROPUM...

Reviews: