0900885 Rev: REL (02/06)
Page 11 of 12
LABEL CHANGE PROCEDURE
(1) Shut off power to the system.
(2) Remove screws that hold the LFP circuit board to the front panel of the control box.
(3) Disconnect ribbon cable from the LFP circuit board.
(4) Use 2 of the screws to temporarily hold the board onto the front panel while changing the label.
(5) Carefully remove old label. Start by prying up on a corner with a sharp edge blade. Use of a heat gun may be
helpful to loosen the adhesive.
(6) Clean old adhesive from the front panel with alcohol in preparation for adhering the new label.
(7) Carefully remove the backing paper from the new label. Route the ribbon cable through the slot in the front panel
and adhere the label in place using the keyhole and LFP window for proper alignment.
(8) Push out any air bubbles that may have gotten trapped while attaching the new label. Work from the middle
region of the label to outer edges.
(9) Remove the 2 screws that were temporarily holding the LFP circuit board in place and attach the ribbon cable.
(10) Re-attach the LFP circuit board back on the front panel using all mounting screws.
(11) Turn power to system back on.
(12) Test each button of the new label to ensure proper function.