background image

 

 

 

3/11

CETE | Global R&D 

November 2017 | V1 

 

INTRODUCTION 

We thank you for choosing a fingerprint acquisition terminal from IDEMIA.  

The  MorphoTop  Slim  provides  an  effective  solution  for  the  fingerprint  acquisition  of  4  fingers 
simultaneously, of two thumbs and of rolled fingers. 

Among  a  range  of  alternative  biometric  technologies,  the  use  of  fingerprints  has  significant 
advantages:  each  fingerprint  constitutes  an  unalterable  physical  signature  which  develops 
before birth and preserves until death. 

The  MorphoTop  Slim  stands  out  as  a  fast,  precise,  easy-to-use  and  ideal  system  for  the 
fingerprint acquisition applications. 

The MorphoTop Slim has the following characteristics: 

 

High quality TFT sensor (500 PPI IQS Appendix F certified), 

 

Compact size for easy installation and fast integration, 

 

Intuitive and easy-to-use Interface, 

 

Open  architecture,  with  dedicated  applications  implemented  via  the  Morpho  LiveScan 
Software Development Kit and MorphoBop SDK. 

To  ensure  the  most  effective  use  of  your  MorphoTop  Slim,  we  recommend  that  you  read  this 
Installation Guide thoroughly. 

 

 

RECOMMENDATIONS 

 

General precautions 

 

Do  not  put  sharp  hard  object  (such  as  but  not  limited  to  screw-driver,  pen,  USB 
connector,..) on the acquisition area.
 MorphoTop Slim sensor is robust as a TFT screen can 
be, so sharp objects could damage the sensor. 

 

Do  not  attempt  to  repair  the  MorphoTop  Slim  yourself.  The  manufacturer  cannot  be  held 
responsible  for  any  damage/accident  that  may  result  from  attempts  to  repair  components.  Any 
work carried out by unauthorized staff will invalidate your warranty. 

 

Do not expose the MorphoTop Slim to extreme temperatures. 

 

Due  to  electrostatic  discharge,  and  depending  on  the  environment,  synthetic  carpet  should  be 
avoided in areas where the MorphoTop Slim has been installed. 

 

Cleaning precautions 

MorphoTop  Slim  is  designed  with  anti-Smudge  coating,  for  easier  clean  purpose.  Clean  periodically 
latent trace with a dry wipe dedicated to optic or TFT screen part; no hard water (acidic/alkaline/ type 
of detergent solvent). If necessary use ethyl alcohol. 
 

Warning 

The manufacturer cannot be held responsible if the above recommendations are not followed or if the 
MorphoTop Slim is incorrectly used.  

Summary of Contents for MorphoTop Slim

Page 1: ...CETE Global R D November 2017 V1 MorphoTop Slim Installation guide...

Page 2: ...tion 4 Caution 4 USA information 4 Caution 4 GENERAL DESCRIPTION 5 RECOMMENDED DEVICE INSTALLATION 6 TECHNICAL CHARACTERISTICS 8 Device Configuration 8 Device Option license containers 8 Man Machine I...

Page 3: ...hoTop Slim we recommend that you read this Installation Guide thoroughly RECOMMENDATIONS General precautions Do not put sharp hard object such as but not limited to screw driver pen USB connector on t...

Page 4: ...ay cause interference In this case the user is encouraged to try to correct the interference with appropriated measures USA information This device complies with part 15 of the FCC Rules Operation is...

Page 5: ...ation for USB2 Acquisition surface Acquisition type indicators 2 mounting holes for M3 screw Acquisition Status indicators Orange means harder pression on related finger is requested USB trapdoor to b...

Page 6: ...NDED DEVICE INSTALLATION To optimize the ergonomic of Thumb acquisition it is advised to set up the product a bit over the table and fixed on the table thanks to the 2 mounting holes defined just befo...

Page 7: ...Use two M3 screws to maintain the product to the table Choose a screw length table thickness 3 to 5 5mm Fix them gently without exceeding max force of 0 9 Nm and with M3 washers 1 1 mm thickness 0 1 m...

Page 8: ...3 x3 2 Size and weight Volume L W H 14 5 x 13 x 2 6 cm3 5 7x5 1x1 Weight 0 4 Kg Power consumption Operating acquisition Typical Vbus 5 0V I 600 mA P 3 W Idle backlight switched off Typical Vbus 5 0V I...

Page 9: ...ugged on the same controller especially high load devices such as hard disk or webcam or another MorphoTOP device It is highly recommended to plug MorphoTop Slim on a USB3 port USB2 port could be not...

Page 10: ...TE Global R D November 2017 V1 Then you will be able to count USB controller on your computer It is highly recommended to have at least 2 controllers 1 for MorphoTop Slim 1 for other devices behind a...

Page 11: ...biometric terminals com Produced by IDEMIA Identity Security France Registered office Adresse 11 boulevard Galli ni 92130 Issy les Moulineaux FRANCE Support For Products sold by other Business Units p...