Operating Instructions
IDEM Safety Switches
UGB-NET-CS
102620 2210 UGB-NET-CS Operating Instructions
6
Network Address
–
Setup/Initial Setting
The UGB-NET IP address can be set via DHCP server or statically via the device DIP switches.
The UGB-NET in its out-of-the-box state will have DHCP enabled (All DIP switches OFF, no IP address set).
Setting via DIP Switch
To manually assign a static IP the DIP switches located on the lid of the UGB-NET are used. The following
steps can be performed with the device powered on or off, note the final step if the device is powered.
1.
Locate the DIP switch cover on the UGB-NET body, remove the 2 cover screws and lift the DIP
switch cover to gain access to the DIP switches.
2.
Using a small tool push the required switches to the ‘ON’ position to set the corresponding bit.
3.
Cycle power to the UGB-NET or press and hold the reset button until the LEDs turn red then release to
reset the device. The UGB-NET will restart with the configured IP address and with DHCP disabled.
4.
Replace the DIP switch cover and screws ensuring a tight seal to the switch housing.
INFORMATION
•
The example given in the image above shows only switches 2, 16 and 64 set to
the ‘ON’ position.
The resulting IP address is: 192.168.1.
82
Setting via DHCP
1.
Apply power to the UGB-NET, after a start-
up period the ‘MS’ LED should be flashing green.
2.
Using a PC station that is configured on the same network as the UGB-NET, run the BOOTP/DHCP tool.
3.
Using the MAC address to identify the UGB-NET, select the UGB-
NET in the ‘Discovery History’ window
an
d click ‘Add Relation’.