Technical Specifications
A-9
IDEC SmartRelay User’s Manual
A.4 Technical Specifications: FL1A-H12RCE,
FL1A-B12RCE
FL1A-H12RCE
FL1A-B12RCE
Power supply
Input voltage
12/24 V DC
Permissible range
10.8 ... 15.6 V DC
20.4 ... 28.8 V DC
Power consumption
10 ... 120 mA
(from 12/24 V DC)
Voltage failure bridging
Typically 5 ms
Power loss
0.1 ... 1.2 W
(at 12/24 V DC)
Clock buffering at 25
_
C
Typically 80 h
Accuracy of the real-time clock
Max.
”
5 s a day
Electrical isolation
No
Reverse polarity protection
Yes
Digital inputs
Number
8
Electrical isolation
No
Input voltage L+
•
Signal 0
•
Signal 1
< 5 V DC
> 8 V DC
Input current at
•
Signal 0
•
Signal 1
< 1.0 mA
> 1.5 mA
Delay time at
•
0 after 1
•
1 after 0
Typically 1.5 ms
Typically 1.5 ms
Line length (unshielded)
100 m
Analog inputs
Number
2 (I7, I8)
Range
0 ... 10 V DC
Summary of Contents for SmartRelay FL1A-B10RCA
Page 1: ...IDEC SmartRelay Manual March 2001 www idec com ...
Page 16: ...Getting to Know IDEC SmartRelay 1 6 IDEC SmartRelay User s Manual ...
Page 32: ...Installing and Wiring IDEC SmartRelay 2 16 IDEC SmartRelay User s Manual ...
Page 132: ...IDEC SmartRelay Functions 4 64 IDEC SmartRelay User s Manual ...
Page 184: ...Applications 8 32 IDEC SmartRelay User s Manual ...
Page 204: ...IDEC SmartRelay Menu Structure E 2 IDEC SmartRelay User s Manual ...
Page 206: ...Type Numbers F 2 IDEC SmartRelay User s Manual ...
Page 208: ...Abbreviations G 2 IDEC SmartRelay User s Manual ...