24:
AS
‐
I
NTERFACE
M
ASTER
C
OMMUNICATION
FC5A
M
ICRO
S
MART
U
SER
’
S
M
ANUAL
FC9Y
‐
B1273
24
‐
37
Monitor
AS
‐
Interface
Slave
While
the
MicroSmart
is
communicating
with
AS
‐
Interface
slaves
through
the
AS
‐
Interface
bus,
operating
status
of
AS
‐
Interface
slaves
can
be
monitored
using
WindLDR
on
a
computer.
Output
statuses
and
parameter
image
(PI)
can
also
be
changed
using
WindLDR
.
To
open
the
Monitor
AS
‐
Interface
Slaves
dialog
box,
from
the
WindLDR
menu
bar,
select
Online
>
Monitor
,
then
select
Online
>
Monitor
Slaves
.
Change
Slave
Output
Statuses
and
Parameters
The
output
statuses
and
parameter
image
(PI)
of
the
slaves
connected
to
the
AS
‐
Interface
master
module
can
be
changed.
To
open
the
Slave
Status
dialog
box,
click
the
output
of
a
required
slave
address
in
the
Monitor
AS
‐
Interface
Slaves
dialog
box.
Then,
click
the
On
or
Off
button
to
change
the
statuses
of
outputs
DO0
through
DO3
and
parameters
P0
through
P3
as
required.
Click
Store
to
save
the
changes
to
the
slave
module.
If
the
command
is
not
processed
correctly,
the
error
message
“AS
‐
Interface
Master
Error”
and
an
error
code
will
appear.
See
38.
The
output
statuses
and
parameters
cannot
be
changed
in
the
following
cases.
Dialog
Box
Button
Description
Monitor
AS
‐
Interface
Slaves
Switch
Slaves
Switches
between
Slave
A
screen
and
Slave
B
screen.
Close
Closes
the
window.
Help
Displays
explanations
for
functions
on
the
screen.
Slave
Status
Store
Stores
output
statuses
and
parameters
to
the
slave.
Close
Closes
the
window.
Error
Code
Description
1
An
error
was
found
on
the
expansion
I/O
bus.
7
The
AS
‐
Interface
master
module
is
in
local
mode.
8
Attempt
was
made
to
change
the
parameters
of
a
slave
which
did
not
exist.
Parameter
Image
(PI)
Summary of Contents for MICROSmart FC5A Series
Page 1: ...FC5A SERIES FC9Y B1273 1 User s Manual Advanced Volume ...
Page 2: ......
Page 8: ...Preface 6 FC5A MicroSmart User s Manual FC9Y B1273 ...
Page 14: ...TABLE OF CONTENTS vi FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 52: ...4 DATA COMPARISON INSTRUCTIONS 4 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 72: ...5 Binary Arithmetic Instructions 5 20 FC5A MicroSmart User s Manual FC9Y B1273 ...
Page 88: ...7 SHIFT ROTATE INSTRUCTIONS 7 12 FC5A MicroSmart User s Manual FC9Y B1273 ...
Page 112: ...8 DATA CONVERSION INSTRUCTIONS 8 24 FC5A MicroSmart User s Manual FC9Y B1273 ...
Page 138: ...11 PROGRAM BRANCHING INSTRUCTIONS 11 14 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 178: ...13 PULSE INSTRUCTIONS 13 32 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 202: ...14 PID INSTRUCTION 14 24 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 206: ...15 DUAL TEACHING TIMER INSTRUCTIONS 15 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 214: ...16 INTELLIGENT MODULE ACCESS INSTRUCTIONS 16 8 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 248: ...21 COMPUTER LINK COMMUNICATION 21 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 272: ...23 MODBUS TCP COMMUNICATION 23 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 332: ...25 EXPANSION RS232C RS485 COMMUNICATION 25 16 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 341: ...NOTE FC5A MICROSMART USER S MANUAL FC9Y B1273 1 ...
Page 342: ...NOTE 2 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...