13:
P
ULSE
I
NSTRUCTIONS
FC5A
M
ICRO
S
MART
U
SER
’
S
M
ANUAL
FC9Y
‐
B1273
13
‐
17
S1+4 Reversible
Control
Enable
The
value
stored
in
the
data
register
designated
by
device
S1+4
specifies
one
of
the
output
modes.
RAMP1
can
designate
0
through
2
for
device
S1+4,
while
RAMP2
can
designate
0
and
1.
If
the
value
stored
in
the
data
register
designated
by
device
S1+4
is
changed
after
the
start
input
for
the
RAMP
instruction
has
been
turned
on,
the
change
can
take
effect
only
after
the
CPU
starts
again.
S1+5 Control
Direction
When
S1+4
is
set
to
1
or
2
to
enable
reversible
control,
the
value
stored
in
the
data
register
designated
by
device
S1+5
specifies
the
control
direction.
0:
Forward
1:
Reverse
S1+6 Preset
Value
(High
Word)
S1+7 Preset
Value
(Low
Word)
The
RAMP1
or
RAMP2
instruction
generates
a
predetermined
number
of
output
pulses
as
designated
by
devices
S1+6
and
S1+7.
The
preset
value
can
be
1
through
100,000,000
(05F5
E100h)
stored
in
two
consecutive
data
registers
desig
‐
nated
by
S1+6
(high
word)
and
S1+7
(low
word).
S1+8 Current
Value
(High
Word)
S1+9 Current
Value
(Low
Word)
While
the
RAMP1
or
RAMP2
instruction
is
executed
to
generate
output
pulses,
the
output
pulse
count
is
stored
in
two
consecutive
data
registers
designated
by
devices
S1+8
(high
word)
and
S1+9
(low
word).
The
current
value
can
be
1
through
100,000,000
(05F5
E100h)
and
is
updated
in
every
scan.
S1+4
Value
Reversible
Control
Description
0
Reversible
control
disabled
Output
Q0
or
Q2
generates
output
pulses;
used
for
single
‐
direction
control.
Output
Q1
can
be
used
for
PULS2,
PWM2,
ZRN2,
or
an
ordinary
output.
When
using
RAMP2,
output
Q3
can
be
used
for
an
ordinary
output.
1
Reversible
control
(Single
‐
pulse
output)
Output
Q0
or
Q2
generates
output
pulses,
and
output
Q1
or
Q3
generates
a
direc
‐
tion
control
signal.
Output
Q1
or
Q3
turns
on
or
off
depending
on
the
value
stored
in
data
register
des
‐
ignated
by
device
S1+5
(control
direction):
0
for
forward
or
1
for
reverse.
2
(RAMP1
only)
Reversible
control
(Dual
‐
pulse
output)
Output
Q0
generates
forward
output
pulses,
and
output
Q1
generates
reverse
out
‐
put
pulses.
Output
Q0
or
Q1
generates
output
pulses
alternately
depending
on
the
value
stored
in
data
register
designated
by
device
S1+5
(control
direction):
0
for
forward
or
1
for
reverse.
Output
Q0/Q2
Output
Q0/Q2
Output
Q1/Q3
Forward
Reverse
Output
Q0
Output
Q1
(Forward)
(Reverse)
Summary of Contents for MICROSmart FC5A Series
Page 1: ...FC5A SERIES FC9Y B1273 1 User s Manual Advanced Volume ...
Page 2: ......
Page 8: ...Preface 6 FC5A MicroSmart User s Manual FC9Y B1273 ...
Page 14: ...TABLE OF CONTENTS vi FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 52: ...4 DATA COMPARISON INSTRUCTIONS 4 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 72: ...5 Binary Arithmetic Instructions 5 20 FC5A MicroSmart User s Manual FC9Y B1273 ...
Page 88: ...7 SHIFT ROTATE INSTRUCTIONS 7 12 FC5A MicroSmart User s Manual FC9Y B1273 ...
Page 112: ...8 DATA CONVERSION INSTRUCTIONS 8 24 FC5A MicroSmart User s Manual FC9Y B1273 ...
Page 138: ...11 PROGRAM BRANCHING INSTRUCTIONS 11 14 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 178: ...13 PULSE INSTRUCTIONS 13 32 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 202: ...14 PID INSTRUCTION 14 24 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 206: ...15 DUAL TEACHING TIMER INSTRUCTIONS 15 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 214: ...16 INTELLIGENT MODULE ACCESS INSTRUCTIONS 16 8 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 248: ...21 COMPUTER LINK COMMUNICATION 21 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 272: ...23 MODBUS TCP COMMUNICATION 23 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 332: ...25 EXPANSION RS232C RS485 COMMUNICATION 25 16 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 341: ...NOTE FC5A MICROSMART USER S MANUAL FC9Y B1273 1 ...
Page 342: ...NOTE 2 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...