8:
D
ATA
C
ONVERSION
I
NSTRUCTIONS
FC5A
MicroSmart
User’s
Manual FC9Y
‐
B1273
8
‐
19
CVDT
(Convert
Data
Type)
Applicable
CPU
Modules
Valid
Devices
For
the
valid
device
address
range,
see
pages
and
(
Basic
Vol.).
Internal
relays
M0
through
M2557
can
be
designated
as
D1.
Special
internal
relays
cannot
be
designated
as
D1.
When
T
(timer)
or
C
(counter)
is
used
as
S1,
the
timer/counter
current
value
(TC
or
CC)
is
read
out.
When
T
(timer)
or
C
(counter)
is
used
as
D1,
the
data
is
written
in
as
a
preset
value
(TP
or
CP)
which
can
be
0
through
65535.
When
F
(float)
data
type
is
selected,
only
data
register
and
constant
can
be
designated
as
S1
and
only
data
register
can
be
designated
as
D1.
When
F
(float)
data
type
is
selected
and
S1
or
D1
does
not
comply
with
the
normal
floating
‐
point
format,
a
user
program
execution
error
will
result,
turning
on
special
internal
relay
M8004
and
ERR
LED
on
the
CPU
module.
Valid
Data
Types
FC5A
‐
C10R2/C/D
FC5A
‐
C16R2/C/D
FC5A
‐
C24R2/C/D
FC5A
‐
D16RK1/RS1
FC5A
‐
D32K3/S3
FC5A
‐
D12K1E/S1E
X
X
X
X
X
X
Device
Function
I
Q
M
R
T
C
D
Constant
Repeat
S1
(Source
1)
First
device
address
to
convert
data
type
X
X
X
X
X
X
X
X
1
‐
99
D1
(Destination
1)
First
device
address
to
store
converted
data
—
X
X
X
X
X
—
1
‐
99
W
(word)
X
I
(integer)
X
D
(double
word)
X
L
(long)
X
F
(float)
X
S1
D1
When
input
is
on,
the
data
type
of
the
16
‐
or
32
‐
bit
data
designated
by
S1
is
converted
and
stored
to
the
destination
designated
by
device
D1.
Data
types
can
be
designated
for
the
source
and
destination,
separately.
When
the
same
data
type
is
designated
for
both
source
and
destination,
the
CVDT
instruction
has
the
same
function
as
the
MOV
instruction.
Unless
F
(float)
data
type
is
selected
for
both
source
and
destination,
only
the
integral
number
is
moved,
omitting
the
fraction.
When
the
source
data
exceeds
the
range
of
destination
data
type,
the
destina
‐
tion
stores
a
value
closest
to
the
source
data
within
the
destination
data
type.
Data
Type
W,
I
D,
L,
F
Source
S1
S1
∙
S1+1
Destination
D1
D1
∙
D1+1
S1(R)
*****
REP
**
D1(R)
*****
CVDT
*TO*
When
a
bit
device
such
as
I
(input),
Q
(output),
M
(internal
relay),
or
R
(shift
register)
is
designated
as
the
source
or
destination,
16
points
(word
or
integer
data
type)
or
32
points
(double
‐
word,
long,
or
float
data
type)
are
used.
When
repeat
is
designated
for
a
bit
device,
the
quantity
of
device
bits
increases
in
16
‐
or
32
‐
point
increments.
When
a
word
device
such
as
T
(timer),
C
(counter),
or
D
(data
register)
is
designated
as
the
source
or
destination,
1
point
(word
or
integer
data
type)
or
2
points
(double
‐
word,
long,
or
float
data
type)
are
used.
When
repeat
is
designated
for
a
word
device,
the
quantity
of
device
words
increases
in
1
‐
or
2
‐
point
increments.
Summary of Contents for MICROSmart FC5A Series
Page 1: ...FC5A SERIES FC9Y B1273 1 User s Manual Advanced Volume ...
Page 2: ......
Page 8: ...Preface 6 FC5A MicroSmart User s Manual FC9Y B1273 ...
Page 14: ...TABLE OF CONTENTS vi FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 52: ...4 DATA COMPARISON INSTRUCTIONS 4 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 72: ...5 Binary Arithmetic Instructions 5 20 FC5A MicroSmart User s Manual FC9Y B1273 ...
Page 88: ...7 SHIFT ROTATE INSTRUCTIONS 7 12 FC5A MicroSmart User s Manual FC9Y B1273 ...
Page 112: ...8 DATA CONVERSION INSTRUCTIONS 8 24 FC5A MicroSmart User s Manual FC9Y B1273 ...
Page 138: ...11 PROGRAM BRANCHING INSTRUCTIONS 11 14 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 178: ...13 PULSE INSTRUCTIONS 13 32 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 202: ...14 PID INSTRUCTION 14 24 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 206: ...15 DUAL TEACHING TIMER INSTRUCTIONS 15 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 214: ...16 INTELLIGENT MODULE ACCESS INSTRUCTIONS 16 8 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 248: ...21 COMPUTER LINK COMMUNICATION 21 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 272: ...23 MODBUS TCP COMMUNICATION 23 10 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 332: ...25 EXPANSION RS232C RS485 COMMUNICATION 25 16 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Page 341: ...NOTE FC5A MICROSMART USER S MANUAL FC9Y B1273 1 ...
Page 342: ...NOTE 2 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...