Functions
68
HR9Z-B2190 8/2020
Configuring the Start Function
The start function is configured by means of the start function selector.
A start function with dynamization is typically if the start input is connected to a start push-button.
A start function without dynamization is typically used if the start input is connected to a logic
controller. Refer to the chapter Dynamization
) for details.
Position of start function selector
Configured start function
1
Automatic/manual start (depends on
sensor/device connected to start input)
Without startup test
With dynamization
2
Automatic/manual start (depends on
sensor/device connected to start input)
With startup test
With dynamization
3
Monitored start
Without startup test
With dynamization
4
Monitored start
With startup test
With dynamization
5
Automatic/manual start (depends on
sensor/device connected to start input)
Without startup test
Without dynamization
6
Automatic/manual start (depends on
sensor/device connected to start input)
With startup test
Without dynamization
7
Monitored start
Without startup test
Without dynamization
8
Monitored start
With startup test
Without dynamization