Chapter 3
Calibration, Configuration, and Special Operations
3-48
Figure 3-6: TDR Graphical Plot Layout and Controls
Note: TDR graphs do not have a tabular view option
Table 3-6: TDR Graphical Plot Layout and Controls
Item
Function
1
Actual TDR data plot for a wire pair. When a wire graph is first
displayed, the cursor is automatically positioned at the midpoint of
the data.
2
Designated wire pair plotted from TDR data. (Pair A, B, C, or D)
3
Distance in meters or feet and impedance value at the cursor.
4
The vertical axis representing percentage of reflection data.
5
The horizontal axis representing distance data.
6
Distance of cursor vs. total length measured in points and associated
measured levels of impedance.
7
Zoom out/Zoom in keys to expand or compress the horizontal axis of
the graph at the cursor.
8
Arrow keys are used to move the cursor horizontally; the screen data
displayed will change to reflect the cursor position.
Summary of Contents for LANTEK
Page 80: ...Chapter 3 Calibration Configuration and Special Operations 3 39 store up to 10 custom cables ...
Page 116: ...Chapter 4 Autotesting 4 24 ...
Page 124: ...Chapter 5 Analyze Testing 5 8 ...
Page 172: ...Chapter 6 Using LANTEK REPORTER 6 48 ...
Page 208: ...Appendix A Safety Precautions A 4 ...