British Gas RD1
-
Installation & Servicing
15
INSTALLATION
FLUE OUTLET
Flue length
for rear
Flue length for side
Jacking screw for
boiler alignment
SIDE FLUE
INSTALLATION
REAR FLUE
INSTALLATION
FLUE KITS
Pack B: supplied as standard.
Pack D*: optional extension kit for side flue or rear flue
outlet. Refer to 'Flue Extension Ducts'
1. A maximum of 3 extension ducts (plus the standard
flue duct) may be used together.
Note.
RD130 Max flue length = 600mm
2. Flue extensions of greater than 1m (39") should be
supported with the bracket provided. If the stand-off
brackets have been used it is necessary, in order to
keep the flue aligned, to use the spacer bracket with
the support bracket.
It is MOST IMPORTANT that the boiler is installed
in a vertical position.
Flue length mm
Accessories
Product No.
Up to 600
B Pack 1 off
150 308
600 to 1550*
B Pack 1 off + D Pack, 1 off
152132
1550 to 2500
B Pack 1 off + D Pack, 2 off
152132, 2 off
2500 to 3000
B Pack 1 off + D Pack, 3 off
152132, 3 off
Note.
Vertex and Roof Flue Kits are available as optional extras
for vertical flue installation, supplied with separate fitting
instructions.
12 DETERMINING THE FLUE LENGTH
cla 7180
13 REAR FLUE ASSEMBLY - Exploded View
LEGEND
1. Terminal.
2. Weather seal.
1. An optional flue duct extension kit is required for
wall thicknesses greater than 600mm (23
1/2
")
Refer to Frame 12.
2. When cutting the ducts, always use the cardboard
support rings provided.
3. Flue assembly.
4. Boiler sealing ring.
5. Flue extension tube.
FLUE OUTLET