![ID View IV-100CD Installation & Operating Manual Download Page 41](http://html1.mh-extra.com/html/id-view/iv-100cd/iv-100cd_installation-and-operating-manual_3564325041.webp)
39
The different command types and their corresponding parameters are as follows:
2.1 Keys and signals
PC Send: <0x41>, <0x01>, <Key Value>, <0x4f>
< The value for a specific front panel key >
KEY_PLAY 1
KEY_STOP 3
KEY_PAUSE 4
KEY_POWER
5
KEY_REC
6
KEY_SETUP
7
KEY_ENTER
8
KEY_CANCEL
9
KEY_SEARCH
10
KEY_DISPLAY
11
KEY_UP
13
KEY_DOWN
14
KEY_LEFT 15
KEY_RIGHT
16
KEY_SCAN_F
19
KEY_SCAN_R
20
KEY_RETURN
21
KEY_MONITOR 36
2.2 COMMAND Types
2.2.0 Command (Main Category=0x02)
2.2.1 Handshake (Second Category=0x01)
PC
Request:
<0x41>,
<0x02>,
<0x01>,
<0x00>,
<0x4f>
DVR Response: <0x41>, <0x02>, <0x01>, <0x00>, <0x4f>
2.2.2 Request Time (Second Category=0x02)
PC Request: <0x41>, <0x02>, <0x02>, <0x00>, <0x4f>
DVR Response: <0x41>, <0x02>, <0x02>, <0x07>, <7 Time Value >, <0x4f>
The following case is an illustration of
< 7 Time Value>
2001/06/20 17:05:00 = <0xD1>,<0x07>, <0x06>,<0x14>, <0x11>,<0x05>, <0x00>