18
4.2.3 Alarm Recording
Take the following steps to activate the programmed alarm recording. For
ALM REC RATE
,
ALM REC
QUALITY
,
ALARM STATUS
,
ALM DURATION
, and
PRE-ALARM
settings, please refer to section 5.4
for more details.
(1) Press the
SETUP
button
to enter the
MAIN MENU
.
(2) Select
ALARM
and press the
ENTER
/
SAVE
ENTER/SAVE
button
to enter the
ALARM SETTING
.
(3) Set the desired
REC RATE, REC QUALITY, ALM TYPE,
and
ALM DURATION
for use. If pre-alarm
recording is required, set
PRE-ALARM
to
ON
.
(4) To activate the alarm recording, set
ALM OPERATION
to
ON
. To deactivate it, set
ALM
OPERATION
to
OFF
.
4.2.4 Externally triggered Recording
By connecting the
REC
exposure contact on the rear panel of the DVR with an external switch, you can
activate/deactivate the recording function of a DVR. The file will be kept with a prefixed
“R”
. Please
refer to section 2.3 for more details.
MAIN MENU
TIME/ TITLE
RECORD TIMER
RECORD
ALARM
COMMUNICATION
DISK
SYSTEM
GOTO ALARM PAGE
ALARM SETTING
ALM OPERATION : OFF
REC RATE
: 60F/S
REC QUALITY
: HIGH
ALM TYPE
: NO
ALM DURATION
: NON STOP
PRE- ALARM
: OFF