background image

FCC Compliance Statements

FCC Rules and Regulations CFR 47, Part 15, Subpart A

This equipment complies with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules.

Operation is subject to the following two conditions:

This device may not cause harmful interference.

This device must accept any interference received, including interference that may cause undesired operation.

NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY
APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S
AUTHORITY TO OPERATE THE EQUIPMENT.

PRT-TS50 | LCD Touchscreen Keypad | Installation Manual

23

Summary of Contents for PRT-TS50

Page 1: ...PRT TS50 Protege LCD Touchscreen Keypad Installation Manual...

Page 2: ...tronic or mechanical for any purpose without the express written permission of Integrated Control Technology Limited Designed and manufactured by Integrated Control Technology Limited Protege and the...

Page 3: ...14 Language 14 Keypad Address 14 Theme 14 Backlight Brightness Setting 14 Screen Timeout Setting 14 Default Configuration 14 Keypad Information 14 Keypad Functions 15 Orientation 16 Status Indicators...

Page 4: ...features for secure ATM and banking vault area access with automatic timeout and delayed opening functions Individual reportable duress code trouble for each Protege keypad Activation of 3 reportable...

Page 5: ...This equipment is to be installed in accordance with The product installation instructions AS NZS 2201 1 Intruder Alarm Systems The Local Authority Having Jurisdiction AHJ PRT TS50 LCD Touchscreen Key...

Page 6: ...unit 2 Hold the rear case half against the wall and mark the mounting holes and cable entry area The cable entry area should align with a hole cut through the plaster wall board Cables are intended t...

Page 7: ...hnical Diagram The dimensions shown below outline the essential details needed to help ensure the correct installation of the LCD Touchscreen Keypad PRT TS50 LCD Touchscreen Keypad Installation Manual...

Page 8: ...RPLE SB YELLOW SA BLUE Output BROWN Input 2 ORANGE Input 1 WHITE NB GREEN NA BLACK 0V RED 12V SHIELD Output Wiring Example 12V 0V RS 485 NA RS 485 NB N C Tamper N C Tamper Input 1 N C Input Contact 1K...

Page 9: ...ation The Protege system incorporates encrypted RS 485 communications technology for its module network Each system controller supports up to 250 keypads PRT TS50 LCD Touchscreen Keypad Installation M...

Page 10: ...ion EOL The EOL End of Line jumper should be placed in the ON position when the keypad is inserted as the first or last module on the RS 485 network EOL Jumper OFF EOL Jumper ON PRT TS50 LCD Touchscre...

Page 11: ...f the input wiring configuration settings that can be programmed under the input options within the Protege software Input No Resistors Input 1K and 1K Input Duplex Mode 1K and 2K4 To utilize the inpu...

Page 12: ...and 3 are pressed together generating a panic message KPXXX 04 Keypad Duress A user code with the duress option enabled has entered a code on the keypad KPXXX 05 Reserved KPXXX 06 Reserved KPXXX 07 To...

Page 13: ...he keypad connector P1 KPXXX 02 Armed status indicator Red KPXXX 03 Disarmed status indicator Green KPXXX 04 Beeper output KPXXX 05 Confidentiality mode Replace xxx with the appropriate address of the...

Page 14: ...he dark or light keypad display configuration Backlight Brightness Setting The backlight brightness setting adjusts the brightness of the screen when the keypad is in use Move the Backlight slider or...

Page 15: ...ogrammed to unlock a door The STAY key is used to initiate the stay arming process for an area The FORCE key is used to force arm an area The MEMORY key will take a user directly to the memory view me...

Page 16: ...browse to the firmware Bin File bin format supplied by ICT 5 Open the file to install the new firmware on the selected keypad When the update is complete the keypad will restart in the new orientatio...

Page 17: ...on the system is disarmed Alternatively when the disarmed indicator is on the system may be ready to arm all inputs are secure Enter your user code to arm This indicator is programmable and may not f...

Page 18: ...ypad that is programmed is beyond the maximum number of keypads that are allowed to connect to the controller Press the EXIT key to restart the keypad Set the keypad address to a lower value Duplicate...

Page 19: ...le for all output functions 2 system status indicators 1 system beeper Dimensions Dimensions L x W x H 131 x 90 x 20mm 5 15 x 3 54 x 0 77 Weight 192g 6 77oz Operating Conditions Operating Temperature...

Page 20: ...d Australia General Product Statement The RCM compliance label indicates that the supplier of the device asserts that it complies with all applicable standards PRT TS50 LCD Touchscreen Keypad Installa...

Page 21: ...opriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordanc...

Page 22: ...with EN 50131 1 Single Button Setting should not be selected To comply with EN 50131 1 only one battery can be connected and monitored per system If more capacity is required a single larger battery...

Page 23: ...nditions This device may not cause harmful interference This device must accept any interference received including interference that may cause undesired operation NOTE THE GRANTEE IS NOT RESPONSIBLE...

Page 24: ...Statement ICES 003 This is a Class A digital device that meets all requirements of the Canadian Interference Causing Equipment Regulations CAN ICES 3 A NMB 3 A PRT TS50 LCD Touchscreen Keypad Install...

Page 25: ...oyees shall be liable under any circumstances to any party in respect of decisions or actions they may make as a result of using this information In accordance with the ICT policy of enhanced developm...

Page 26: ...aimer Whilst every effort has been made to ensure accuracy in the representation of this product neither Integrated Control Technology Ltd nor its employees shall be liable under any circumstances to...

Reviews: