background image

European Standards

CE Statement

Conforms where applicable to European Union (EU) Low Voltage Directive (LVD) 2014/35/EU, Electromagnetic
Compatibility (EMC) Directive 2014/30/EU, Radio Equipment Directive (RED)2014/53/EU and RoHS Recast
(RoHS2) Directive: 2011/65/EU + Amendment Directive (EU) 2015/863.

This equipment complies with the rules, of the Official Journal of the European Union, for governing the Self
Declaration of the CE Marking for the European Union as specified in the above directive(s).

WEEE

Information on Disposal for Users of Waste Electrical & Electronic Equipment

This symbol on the product(s) and / or accompanying documents means that used electrical and electronic
products should not be mixed with general household waste. For proper treatment, recovery and recycling, please
take this product(s) to designated collection points where it will be accepted free of charge.

Alternatively, in some countries you may be able to return your products to your local retailer upon purchase of an
equivalent new product.

Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on
human health and the environment, which could otherwise arise from inappropriate waste handling.

Please contact your local authority for further details of your nearest designated collection point.

Penalties may be applicable for incorrect disposal of this waste, in accordance with your national legislation.

For business users in the European Union

If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further
information.

Information on Disposal in other Countries outside the European Union

This symbol is only valid in the European Union. If you wish to discard this product please contact your local
authorities or dealer and ask for the correct method of disposal.

EN50131 Standards

This component meets the requirements and conditions for full compliance with EN50131 series of standards for
equipment classification.

EN 50131-1:2006+A2:2017, EN 50131-3:2009, EN 50131-6:2008+A1:2014, EN 50131-10:2014, EN 50136-1:2012, EN
50136-2:2013, EN 60839-11-1:2013

Security Grade 4
Environmental Class II

Equipment Class: Fixed
Readers Environmental Class: IVA, IK07
SP1 (PSTN – voice protocol)
SP2 (PSTN – digital protocol)
SP6 (LAN – Ethernet) and DP1 (LAN – Et PSTN)
SP6 (LAN – Ethernet) and DP1 (LAN – Et USB-4G modem)

Tests EMC (operational

) according to EN 55032:2015

Radiated disturbance

EN 55032:2015

Power frequency magnetic field immunity tests

(EN 61000-4-8)

EN50131

In order to comply with EN 50131-1 the following points should be noted:

PRT-HZX16-DIN | Protege Half DIN Rail 16 Input Expander | Installation Manual

22

Summary of Contents for PRT-HZX16-DIN

Page 1: ...PRT HZX16 DIN Protege Half DIN Rail 16 Input Expander Installation Manual...

Page 2: ...chanical for any purpose without the express written permission of Integrated Control Technology Limited Designed and manufactured by Integrated Control Technology Limited Protege and the Protege Logo...

Page 3: ...ower Indicator 15 Input Indicators 16 Error Code Indication 17 Error Code Display 17 Mechanical Diagram 18 Mechanical Layout 19 Technical Specifications 20 New Zealand and Australia 21 European Standa...

Page 4: ...UL1610 34 FCC Compliance Statements 36 Industry Canada Statement 37 Disclaimer and Warranty 38 PRT HZX16 DIN Protege Half DIN Rail 16 Input Expander Installation Manual 4...

Page 5: ...be connected to the RS 485 module network Up to 250 modules can be connected to the Protege system in any combination to the network over a distance of up to 900M 3000ft Further span can be achieved...

Page 6: ...oring Station Burglar Alarm Systems CAN ULC S302 Installation and Classification of Burglar Alarm Systems for Financial and Commercial Premises Safes and Vaults CAN ULC S561 Installation and Services...

Page 7: ...per wire or wires of the appropriate gauge Earth Ground Connection The DIN rail enclosure and the DIN rail modules must be grounded to a suitable single point earth ground connection in the installati...

Page 8: ...Rail Enclosure DIN Rail Enclosure Module Network RS 485 N N NA and NB DIN Rail Ground Connections multiple cabinets in different rooms sectors or buildings The Dialer s Earth Ground Connection applie...

Page 9: ...ss for wiring It is also recommended that the module is installed in an electrical room communication equipment room secure cabinet or in an accessible area of the ceiling 1 Position the DIN rail modu...

Page 10: ...s to be observed MODULE NETWORK WIRING Recommended Belden 9842 or equivalent 24AWG twisted pair with characteristic impedance of 120ohm or CAT5e CAT6 are also supported for data transmission when usin...

Page 11: ...ltage to all devices on the RS 485 network Warning The 12V N and N communication input must be supplied from only one point Connections from more than one 12V supply may cause failure or damage to the...

Page 12: ...wire tampered in the line occurs When using the EOL resistor configuration the EOL resistor option must be enabled in the input programming so that the tamper and short states can be monitored For mo...

Page 13: ...following table details the trouble inputs that are configured in the system and the trouble type and group that they activate Input Number Description Type Group ZXxxx 01 15 Reserved None None ZXxxx...

Page 14: ...e product Refer to the Protege system controller installation manual for address programming details The controller has a set limit on the number of modules of each type that it can support When addin...

Page 15: ...e update or the identification time period expiring the module will return to normal operation Fault Indicator The fault indicator is lit any time the module is operating in non standard mode If the f...

Page 16: ...t verification of inputs without the need to view the inputs from the keypad or the Protege software State Description Constantly off Input is not programmed Constantly on red Input is in an open stat...

Page 17: ...e feature in the controller s web interface 3 Address Too High The module address is above the maximum number available on the system controller To clear this error change the address to one within th...

Page 18: ...he correct installation of the input expander Status Indicators Input Indicators Inputs 13 16 12VDC Pass Through Inputs 5 8 12VDC Input 12VDC Pass Through RS 485 Input 12VDC Pass Through Inputs 1 to 4...

Page 19: ...ntial details needed to help ensure correct installation and mounting All measurements are shown in millimeters 90 00 78 40 44 68 67 18 4 67 Screw Hole 39 20 39 20 78 40 17 55 35 40 Back Front PRT HZX...

Page 20: ...to 55 C 14 to 131 F Storage Temperature 10 to 85 C 14 to 185 F Humidity 0 93 non condensing indoor use only relative humidity Mean Time Between Failures MTBF 784 316 hours calculated using RFD 2000 UT...

Page 21: ...General Product Statement The RCM compliance label indicates that the supplier of the device asserts that it complies with all applicable standards PRT HZX16 DIN Protege Half DIN Rail 16 Input Expand...

Page 22: ...your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with your national legislation For...

Page 23: ...one input for masking To comply with EN 50131 1 Do not fit more than 10 unpowered detectors per input Do not fit more than one non latching powered detector per input Do not mix unpowered detectors an...

Page 24: ...k General Product Statement The UKCA Compliance Label indicates that the supplier of the device asserts that it complies with all applicable standards PRT HZX16 DIN Protege Half DIN Rail 16 Input Expa...

Page 25: ...6 86 CAN ULC S319 EN DIN 24 EN DIN 24 ATTACK P UL ULC All cabinet installations of this type must be located inside the Protected Area Not to be mounted on the exterior of a vault safe or stockroom Al...

Page 26: ...Time The Protege controller is compatible with the ArmorIP Internet Monitoring Receiver Poll Time must be set to 40 seconds and the Grace Time must be set to 20 seconds In the Protege system the repo...

Page 27: ...vice This will occur automatically with the above programming Status Change Signal An attempt to send a status change signal shall utilize both primary and secondary communication channels Local Annun...

Page 28: ...igital subscriber line DSL modems and F Cable modems Backup Power Requirements Power for network equipment such as hubs switchers routers servers modems etc shall be backed up or powered by an uninter...

Page 29: ...ommunication a digital alarm communicator transmitter shall make a minimum of 5 and a maximum of 10 attempts Where the maximum number of attempts to complete the sequence is reached an indication of t...

Page 30: ...hat the shorts and other faults on the RS 485 line connection of the keypad will not cause the controller to malfunction Fire Areas Fire areas shall be separated from burglar areas through area partit...

Page 31: ...ort 4K7 2K2 Open Close Tamper Short 4K7 4K7 Open Close Tamper Short AUX Z1 COM COM Z2 Z3 Z4 N C T amper N CZoneContact Value2 Value1 Fire zones shall be separated from burglar zones through area parti...

Page 32: ...n Close Tamper Short 4K7 2K2 Open Close Tamper Short 4K7 4K7 Open Close Tamper Short AUX Z1 COM COM Z2 Z3 Z4 N C T amper N CZoneContact Value2 Value1 ULCcertified12VDCPower Supply 12VDC 12VDC AUX 12VD...

Page 33: ...2 Open Close Tamper Short 4K7 4K7 Open Close Tamper Short AUX Z1 COM COM Z2 Z3 Z4 N C T amper N CZoneContact Value2 Value1 ULCcertified12VDCPower Supply 12VDC 12VDC AUX 12VDC 485 485 C NC NC C 12VDC A...

Page 34: ...arming acknowledgement signal must be listed to a UL security signaling or fire standard If intended to be mounted outside it must be rated for outdoor use Exit and entry delay must not exceed 60 sec...

Page 35: ...e selected as Contact ID must have the number of attempts programmed to 5 attempts The following options are required The Dial Attempts option must be programmed Refer to the section Contact ID Settin...

Page 36: ...is device may not cause harmful interference This device must accept any interference received including interference that may cause undesired operation NOTE THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHA...

Page 37: ...is class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada CAN ICES 3 A NMB 3 A PRT HZX16 DIN Protege Half DIN Rail 16 I...

Page 38: ...be liable under any circumstances to any party in respect of decisions or actions they may make as a result of using this information In accordance with the ICT policy of enhanced development design...

Page 39: ...eserved Disclaimer Whilst every effort has been made to ensure accuracy in the representation of this product neither Integrated Control Technology Ltd nor its employees shall be liable under any circ...

Reviews: