Summary of Contents for Protege PRT-IPIC-POE-C

Page 1: ...PRT IPIC POE C Protege Vandal Resistant VoIP Intercom with Camera Installation Manual...

Page 2: ...hanical for any purpose without the express written permission of Integrated Control Technology Limited Designed and manufactured by Integrated Control Technology Limited Protege and the Protege Logo...

Page 3: ...allation 11 Wall Mounting Installation 11 Flush Mounting Installation 14 Flush Mounting Installation with Kit 17 Hardware Configuration 21 Power on Sequence 21 Finding the Intercom on the Network 21 D...

Page 4: ...ificates 37 Intercom Settings Device Certificates 37 LED 37 Security Settings 38 Function Key 40 Main Secondary Operation 40 Day Night Operation 40 Standalone Functionality 42 Unlock a Door with Your...

Page 5: ...8 Technical Specifications 49 New Zealand and Australia 51 European Standards 52 FCC Compliance Statements 54 Industry Canada Statement 55 Disclaimer and Warranty 56 PRT IPIC POE C Vandal Resistant Vo...

Page 6: ...button can be programmed to dial a phone number or call another VoIP device Programmable auto answer Interact with the Protege controller to control devices such as lights and doors Allows local door...

Page 7: ...mended for multiple intercom installations or simply connect the intercom and the controller to the building s existing network When installing an ethernet connection the intercom should be interfaced...

Page 8: ...with the option to use static addressing RTP SRTP Audio Encodings G 711U PCMU G 711A PCMA G 722 G 723 1 G 726 32 G 729AB SIP Servers The intercom supports SIP servers that comply with SIP protocol st...

Page 9: ...or configuration details see page 44 Onboard Outputs There is one onboard Form C relay output This is a standalone output that can be used to control devices such as door locks or lights directly from...

Page 10: ...ode When the output device current is more than 12v 650mA the external drive mode is required The control output interface is for short circuit output control Active mode When the output device curren...

Page 11: ...on L shaped hex tool supplied Phillips screwdriver Ph2 or Ph3 Electric impact drill with 6mm drill bit Hammer RJ45 crimper Parts Check the contents of the accessory parts supplied 1x L shaped hex tool...

Page 12: ...de and intercom Preparation Prepare the installation area 1 Place the wall mounting template sheet on the wall where the intercom will be located 2 Drill 4 holes over the marks provided on the templat...

Page 13: ...nect to the intercom board connectors RJ45 Power Electric Lock 2 Refer to the Connections page see page 9 3 To test press the key on the circuit board for 3 seconds to obtain the IP address of the int...

Page 14: ...ex tool supplied Phillips screwdriver Ph2 or Ph3 Electric impact drill with 6mm drill bit Hammer RJ45 crimper Parts Check the contents of the accessory parts supplied 1x L shaped hex tool 5x 35mm scre...

Page 15: ...intercom Preparation Prepare the installation area 1 The recess cavity should be 235 135 48mm 2 Place the back panel in the cavity where the intercom will be located and mark the 4 screw holes 3 Drill...

Page 16: ...9 3 To test press the key on the circuit board for 3 seconds to obtain the IP address of the intercom unit Do Not proceed until the electric checks are confirmed Completion 1 Attach the intercom to t...

Page 17: ...ox Tools The following tools will be required to complete the installation L shaped hex tool supplied Phillips screwdriver Ph2 or Ph3 Electric impact drill with 6mm drill bit Hammer RJ45 crimper Parts...

Page 18: ...ll the cable through the cable hole in the brick box leaving 15 20cm excess cable length 2 Using the 4 TA5 40mm screws mount the brick box inside the wall cavity Note the brick box should be as close...

Page 19: ...ewdriver remove the 6 main screws and separate the back panel Mounting Pull the cable through the cable hole in the back panel leaving 15 20cm excess cable length Note the intercom is equipped with a...

Page 20: ...the electric checks are confirmed Completion 1 Attach the intercom to the back panel 2 Using 4 M4 35mm screws attach the intercom into the brick box and seal the gap between the frame panel and wall...

Page 21: ...known 1 Ensure the intercom is powered on 2 Remove the screws using the hex key provided and remove the front panel 3 Lift the main body of the intercom out of the enclosure 4 Locate and press the lab...

Page 22: ...tic IP address in the 192 168 10 xxx range xxx can be from 2 254 3 Remove the power to the intercom 4 Put the intercom into Update Mode by holding down the and buttons then connecting power After 5 se...

Page 23: ...ted by ICT or the integration and as such those options are not documented here Accessing the Web Interface 1 Open a web browser and enter the default IP address of the intercom 192 168 1 128 2 When p...

Page 24: ...IP or URL usually the same as the SIP Registrar Server SIP Proxy Server Port Proxy server port Usually 5060 3 Click Apply If the SIP account is correctly configured the Line Status should display Acti...

Page 25: ...P Accounts Displays the phone numbers and registration status for the SIP Lines if configured System Account Enables management of users including adding and removing users and changing passwords and...

Page 26: ...d user 3 New Password Enter the new password to assign for the user to log in 4 Confirm Password Repeat the new password 5 Privilege Set the privilege level for the selected user 6 Click Apply to appl...

Page 27: ...is will take some time as the new configuration settings are uploaded The web interface will display progress and a successfully completed message at the end The device will then perform a Reboot befo...

Page 28: ...rameters are provided by the network administrator DHCP Network parameters are provided automatically by a DHCP server PPPoE This feature is not supported Note Any changes made on this page require a...

Page 29: ...on certificate must be downloaded to the intercom before using HTTPS HTTPS Certification File Click Select to browse and select the required certification file Click Upload to load the file to the dev...

Page 30: ...sword SIP registration password Activate This option must be selected to activate the line SIP Proxy Server Address Proxy server IP or URL usually the same as the SIP Registrar Server SIP Proxy Server...

Page 31: ...egistration Expiration The SIP expiration frequency Use VPN Set the line to use a restricted VPN Use STUN Set the line to use STUN for NAT traversal Convert URI Convert non alphanumeric characters to...

Page 32: ...s Local SIP Port The port the intercom uses to connect to the SIP server The default Local Port is 5060 This may be adjusted if required by the network administrator Registration Failure Retry Interva...

Page 33: ...Line Action Plan This feature is not supported PRT IPIC POE C Vandal Resistant VoIP Intercom with Camera Installation Manual 33...

Page 34: ...cription The broadcast identification of the intercom Enable DND Do Not Disturb Prevents incoming calls according to the DND Mode Outgoing calls will not be affected HangUp Delay The duration in secon...

Page 35: ...Video Capture IRCUT Mode When set to Auto switching of the IRCUT is determined by the ambient light level of the camera When set to Sync switching is determined by the brightness of the IR lamp White...

Page 36: ...ate Dependent on other settings Recommended to leave at default I Frame Interval Dependent on other settings Recommended to leave at default Activate Select to enable disable the Main Stream or Sub St...

Page 37: ...r Secondary Time Server Set the address of the secondary time server Select the appropriate Time Zone Set the Resync Period in seconds for the device to resynchronize time with the server 60 seconds i...

Page 38: ...alert triggers that will activate the onboard output Input Trigger Whenever the input configuration meets the trigger condition the output will be triggered Reset Mode The triggered output can be rese...

Page 39: ...amper Alarm Settings Tamper Alarm Select to enable the tamper alarm Alarm Command Message sent as a SIP message when a tamper alarm is triggered Reset Command Message which should be received from the...

Page 40: ...he call button can be used to end a call Hot Key Dial Mode Select When set to Main Secondary Number 2 will be called when the first number is not answered The Call Switched Time defines the delay in s...

Page 41: ...ring night hours 4 Select the corresponding Line Line 1 or Line 2 for the SIP account 5 From the Subtype list select Speed Dial Advanced Settings 1 Hot Key Dial Mode Select set to Day Night and click...

Page 42: ...sed when activated When set to Low Level NO open the normally open contact will be closed when deactivated and open when activated 4 In the Alert Trigger Setting Output section check Remote DTMF Trigg...

Page 43: ...ctivated When set to Low Level NO open the normally open contact will be closed when deactivated and open when activated 6 Set the Output Duration to the duration in seconds the door should unlock for...

Page 44: ...ngs menu 4 In the Server Settings section set the Server Address to the IP address of the Protege controller 5 Click Apply to update Configuring the Onboard Input as a Protege Input The intercom s onb...

Page 45: ...11 In the pop up window locate the new Keypad record identified by the Address assigned above 12 Check that the Registered and Online columns display True If so the intercom is successfully connected...

Page 46: ...urity Settings menu 2 In the Input Settings section check Input Detect Set the Trigger Mode to High Level Trigger Disconnect Trigger Check Alert message send to server 3 In the Output Settings section...

Page 47: ...Schematic Diagram Installed with Rain Shade Installed with optional Flush Mount Kit PRT IPIC POE C Vandal Resistant VoIP Intercom with Camera Installation Manual 47...

Page 48: ...Wall Mounting Template PRT IPIC POE C Vandal Resistant VoIP Intercom with Camera Installation Manual 48...

Page 49: ...eech flow Protocols RTP SRTP Decoding G 722 G 711U G 711A G 723 1 G 726 32 G 729AB Codecs Audio Amplifier 3W Volume Control Adjustable Full duplex speakerphone Support AEC Port Recording output One 3...

Page 50: ...Humidity 10 to 90 Integrated Control Technology continually strives to increase the performance of its products As a result these specifications may change without notice We recommend consulting our...

Page 51: ...eneral Product Statement The RCM compliance label indicates that the supplier of the device asserts that it complies with all applicable standards PRT IPIC POE C Vandal Resistant VoIP Intercom with Ca...

Page 52: ...handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with your n...

Page 53: ...1 1 Single Button Setting should not be selected To comply with EN 50131 1 only one battery can be connected and monitored per system If more capacity is required a single larger battery must be used...

Page 54: ...device may not cause harmful interference This device must accept any interference received including interference that may cause undesired operation NOTE THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGE...

Page 55: ...ES 003 This is a Class A digital device that meets all requirements of the Canadian Interference Causing Equipment Regulations CAN ICES 3 A NMB 3 A PRT IPIC POE C Vandal Resistant VoIP Intercom with C...

Page 56: ...e liable under any circumstances to any party in respect of decisions or actions they may make as a result of using this information In accordance with the ICT policy of enhanced development design an...

Page 57: ...aimer Whilst every effort has been made to ensure accuracy in the representation of this product neither Integrated Control Technology Ltd nor its employees shall be liable under any circumstances to...