INTRODUCTION 

Pro Series power supplies from ICT provide a  reliable 690  or 1200 Watts of rack-
mountable  dc  power  with  optional  built-in  battery  back-up  support  and  a  low 
volta

ge  disconnect  (LVD,  option  “B”)

  to  power  12,  24,  or  48Vdc  based  systems. 

With  an  efficient  wide  range  power  factor  corrected  input  the  units  are  useable 
world-wide,  and  their  built  in  rack  mounting  ears  and  bus-bar  outputs  make 
installation simple. 
 

 

Wide range Power Factor corrected AC input supports operation world 
wide 

 

Dedicated independently controlled backup battery port with LVD relay 

(units with LVD option “B”)

 

 

Selectable charge rates to accommodate lower capacity batteries (units 

with LVD option “B”)

 

 

Remote on/off control input for external control of the output 

 

Floating Form-C alarm contact output supports remote monitoring of unit 
operation 

 

Model

1

 

Output 

Voltage (V) 

Max Output 

Current (A) 

Continuous 

Current (A) 

ICT690-12S(B) 

13.8 

50 

50 

ICT690-24S(B) 

27.6 

25 

25 

ICT690-48S(B) 

55.2 

12.5 

12.5 

ICT1190-12S(B) 

13.8 

100 

87 

ICT1190-24S(B) 

27.6 

50 

44 

ICT1190-48S(B) 

55.2 

25 

22 

 

CHECK and CONFIGURE UNIT 

Perform a quick physical check of the unit as it is being taken out of the box to 
ensure it has not been damaged during shipping. Check for the included parts and 
accessories shipped with your unit: 
 

 

5 pin Form-C alarm/remote connector plug (installed on unit) 

 

Power cord (North America 120V 15A) 

 

(3 for “B” units) ¼

-20 Hex bolt, washer, nut sets for bus bar connections 

 

Output connector shield (installed over output bus bars) 

 

Instruction Manual 

 

 

                                                 

1

 

Model 

suffix “B”

 denotes units equipped with the optional LVD Battery port

 

Summary of Contents for Pro Series

Page 1: ...upply INSTRUCTION MANUAL 855 343 001 Innovative Circuit Technology Ltd Models ICT690 12S ICT690 12SB ICT690 24S ICT690 24SB ICT690 48S ICT690 48SB ICT1190 12S ICT1190 12SB ICT1190 24S ICT1190 24SB ICT...

Page 2: ...cuit breaker Ensure battery polarity is correct before connecting Do not attempt to charge a frozen battery Handle batteries with care never short circuit battery terminals CAUTION Risk of personal in...

Page 3: ...Innovative Circuit Technology Ltd 3 Table of Contents INTRODUCTION 4 CHECK and CONFIGURE UNIT 4 INSTALLATION 6 OPERATION 7 Status Indicators and Alarms 9 PRODUCT SPECIFICATIONS 10 LIMITED WARRANTY 12...

Page 4: ...on B Remote on off control input for external control of the output Floating Form C alarm contact output supports remote monitoring of unit operation Model1 Output Voltage V Max Output Current A Conti...

Page 5: ...Pro Series unit must be protected using an outlet with a branch rated circuit breaker of 20A or lower value Connection Diagram Showing Rear Connectors and SW Switch 1 4 Configure the Output Settings A...

Page 6: ...sconnect Reconnect V Switch Settings 1 UP 0 Down x either INSTALLATION Mount the unit in a standard 19 inch equipment rack ensuring side air vents are not blocked using rack mounting screws not suppli...

Page 7: ...Connect the remote on off control or unit form C alarm contact monitoring wiring to the REMOTE connector if needed as shown in the following table Pin Number Name Function 1 Shutdown Remote output sh...

Page 8: ...able on page 5 while the output voltage will be determined by the battery state of charge and will rise to the output float voltage over time The battery will be maintained at the supply output float...

Page 9: ...l Battery power only CLOSED ON Battery Low when AC Off Triggers when battery voltage falls below the LVD threshold OFF OPEN ON System Fault Indicates internal circuit fault Clears when all fault condi...

Page 10: ...0W 690W 1200W 690W 1200W 690W Output Noise max mVrms 30 30 30 30 40 40 Input Current max at 120Vac 12A 7A 12A 7A 12A 7A LVD Threshold V Default 11 5V 11 5V 23 0V 23 0V 46 0V 46 0V LVD Reconnect V Defa...

Page 11: ...nst harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause...

Page 12: ...repair The Purchaser shall at their own risk and cost return the defective product to ICT s factory or designated repair center once an RMA is issued by ICT Return of the products to the customer afte...

Page 13: ...nce or causes external to the unit including but not limited to general environmental conditions such as rust corrosive atmospheres sustained temperatures outside the specified operating range of the...