Innovative Circuit Technology Ltd.
15
Network:
MAC Address:
Displays the MAC address assigned to the inverter.
Enable DHCP
: Check this box (default) to turn on this setting if your network
uses a DHCP server to automatically assign IP addresses. To manually assign a
static IP address to the unit, uncheck this box and then set the following
parameters.
IP Address
: Enter a unique IP address for the unit.
Subnet Mask:
Enter the mask for the subnet the inverter is located on.
Gateway:
Enter the IP address of the default router (Gateway) used for
connecting attached devices to different networks.
Primary DNS
: Enter the IP address of the Primary DNS Server for your
network.
Secondary DNS
: Enter the IP address of the Secondary DNS Server for your
network.
Web Server:
CAUTION:
Changing the web server port numbers may cause loss of communication with
the inverter.
The following ports may be changed within a range of 1 to 65565, if required.
HTTP Port
: Enter an HTTP port within the range of 1 to 65565. This port is used
for HTTP traffic between the inverter and your browser. The default HTTP port
is
80
, and if you change this, the new HTTP port number must be appended to
the URL used to access the inverter (e.g. use URL
for IP address
192.168.0.180
, port
8000
).
HTTPS Port
: Enter an HTTPS (HTTP Secure) port within the range of 1 to 65565.
This port is used for HTTPS traffic between the panel and the browser. This
protocol uses encrypted data transfer between the panel and browser for
higher security. The default HTTPS port is
443
. If a new HTTPS port is selected
then the new HTTPS port number must be appended to the URL used to access
the panel (e.g. use URL
https://192.168.0.180:8888
for IP address
192.168.0.180
, port
8888
).