TROUBLESHOOTING
•
CHOP SAW WON’T REACH FULL RPM
– Air filter or pre filter may be dirty.
•
WATER NOT FLOWING
– Water hose is kinked or supply is not turned on.
•
WON’T START
– Turn ignition switch on or possible defective spark plug.
•
WON’T START
– Low compression, less than 120 psi (8 bar). Possible incorrect fuel mixture.
Reference: new = 150 to 180 psi (10 to 12 bar)
used = 140 to 160 psi (9 to 11 bar)
•
DIFFICULT TO START
– Possible flooded engine. Turn ignition switch on, push choke in, hold
throttle on full with foot and pull starter cord until engine starts.
•
DIFFICULT TO START
– Possible fouled spark plug. Remove spark plug, clean with wire brush
and re-gap.
Further questions?
Call 1-800-321-1240