Auto Sentry® Petro - Installation Guide
6
Site Layout
Conduit Wiring Guidelines
All conduit must be rigid PVC or metal.
High-voltage (AC) and low-voltage (DC) must not be combined in a common conduit, junction
box, or wire trough.
Equipment Dimensions, Measurements, and Ratings
When mounting the unit, minimum clearances must meet local recommended standards.
Dimension
Amount
Notes
Width
32 1/2”
—
Height
55 1/2''
—
Depth
17''
Includes heat exchanger cover panel.
Weight
250 lbs.
—
Operating
Temperature Range
-20 °F to 120 °F
-29 °C to 48 °C
—
Frequency
50/60 Hz
—
Supply Voltage
120 VAC
Intended for permanently connected supply.
Max. Amps.
10 Amps @ 120 VAC
6 Amps @ 240 VAC
—
IPX Rating
NEMA 4X
Enclosures constructed for either indoor or outdoor use to
provide a degree of protection to personnel against inci
-
dental contact with the enclosed equipment; to provide a
degree of protection against falling dirt, rain, sleet, snow,
windblown dust, splashing water, and hose-directed water
from water jets at any direction; and that will be undam
-
aged by the external formation of ice on the enclosure.
Including protection against corrosion.
Table 1: Dimensions, Measurements and Ratings