9
1.2
IR speed dome and network IR speed dome installation
1.2.1 Speed dome bracket installation
The speed dome has several types of installation brackets. You can refer to the following
contents for detailed information. Here we are going to install the IR speed dome in wall mount
bracket.
1.2.2 Pipe thread bracket installation
Please connect the quick installation port to the wall mount bracket (Pipe thread connection) and
then use the M4 stainless steel bolt to fix securely. Then you can connect the integrated cable to
the composite cable of the flanges. Please connect the corresponding power cable, video output
cable; RS 485 control cable, network cable, alarm input and output cable respectively (Please
connect as your actual requirements). Finally, you can connect the flange to the quick installation
port. See
Figure
1-1
.
Please note the analog speed dome does not have the network cable connection. You can
connect the RS485, video output cable if necessary..
Wall mount bracket
M4 bolt
Quick
installation port
Flange
Waterproof
composite cable
Flange Installation
Speed Dome