background image

 

7

z

 

We are not liable for any problems caused by unauthorized modifications or attempted repair.

 

 

Do not allow other object falling into the device  

z

 

Please make sure there is no metal or inflammable, explosive substance in the speed dome. 

z

 

The above mentioned objects in the device may result in fire, short-circuit or damage.  

z

 

Please shut down the device and disconnect the power cable if there is water or liquid falling 

into the camera. Please contact your local retailer ASAP. 

z

 

Please pay attention to the camera. Avoid the sea water or rain to erode the camera. 

 

 

Handle carefully  

Do not allow this series product fall down to the ground.  

Avoid heavy vibration. 

 

 

Installation Environment Requirement 

z

 

This series speed dome should be installed in a cool, dry place away from direct sunlight, 

inflammable, explosive substances and etc. 

z

 

This series product shall be away from the strong electromagnetism radiant, please keep it 

away from wireless power, TV transmitter, transformer and etc. 

 

 

Daily Maintenance  

z

 

Please use the soft cloth to clean dust on the shell, or you can use soft cloth with cleaning 

liquid to clean the shell and then use soft cloth to make it dry. 

z

 

Do not use gasoline, dope thinner or other chemical material to clean the shell. It may result 

in shell transfiguration or paint flake. 

z

 

Do not allow the plastic or rubber material to touch the shell for a long time. It may result in 

paint flake. 

 

 

Summary of Contents for ICIPP3020HDIR

Page 1: ...IR Speed Dome Installation Manual Version 2 0 ...

Page 2: ... 4 Address and Baud Rate Setup 10 1 2 5 Install the IR speed dome and then connect the cable 11 1 2 6 Secure the speed dome to the flange 12 1 3 Initial Setup 12 1 4 Dial Switch Setup 12 1 4 1 Communication protocol and Baud rate 13 1 4 2 Address Setup 14 2 BRACKET DIMENSIONS 15 2 1 Wall mount bracket 15 2 2 Hanging mount bracket Multiple Lengths 15 2 3 Corner mount bracket 16 2 4 Pole mount brack...

Page 3: ...nstallation Steps 19 5 CORNER MOUNT BRACKET INSTALLATION 21 5 1 Component Installation 21 5 2 Installation 21 5 2 1 Installation Requirements 21 5 2 2 Installation Steps 21 6 POLE MOUNT BRACKET INSTALLATION 23 6 1 Installation 23 6 1 1 Installation Requirements 23 7 APPENDIX Ⅰ THUNDER PROOF AND SURGE PROTECTION 25 8 APPENDIX Ⅱ ABOUT RS485 BUS 26 8 1 RS485 Bus Main Feature 26 8 2 RS485 Bus Transmis...

Page 4: ...4 8 3 The Problem in Practical Use 26 8 4 RS485 Bus FAQ 27 9 APPENDIX Ⅲ THE RELATIONSHIP BETWEEN THE 24V AC CABLE DIAMETER AND THE TRANSMISSION DISTANCE 28 10 APPENDIX IV WIRE GAUGE REFERENCE SHEET 29 ...

Page 5: ...5 Welcome Thank you for purchasing our speed dome Please read the following safeguards and warnings carefully before you install or use the product ...

Page 6: ...ed dome installation mode and use the lifting appliances at the safety environment z The lifting appliances shall have the enough capacity to reach the installation height z The lifting appliances shall have safe performance Precautions Safety Transportation z Heavy stress violent vibration or water splash are not allowed during transportation storage and installation z This series product must us...

Page 7: ...ies product fall down to the ground Avoid heavy vibration Installation Environment Requirement z This series speed dome should be installed in a cool dry place away from direct sunlight inflammable explosive substances and etc z This series product shall be away from the strong electromagnetism radiant please keep it away from wireless power TV transmitter transformer and etc Daily Maintenance z P...

Page 8: ...e bracket can support the speed dome and its corresponding installation component The safety factor shall be 4X About cable Please select the cable according to your transmission distance The minimum video coaxial cable requirement is z 75 ohm z Full cable with copper conductor z 95 knitted copper shield International Model Max Distance Ft M RG59 U 750ft 229m RG6 U 1 000ft 305m RG11 U 1 500ft 457m...

Page 9: ...e M4 stainless steel bolt to fix securely Then you can connect the integrated cable to the composite cable of the flanges Please connect the corresponding power cable video output cable RS 485 control cable network cable alarm input and output cable respectively Please connect as your actual requirements Finally you can connect the flange to the quick installation port See Figure 1 1 Please note t...

Page 10: ...nnected the flange to the speed dome please install it to the bracket Use the three inner hex screws to secure See Figure 1 2 For the corner mount installation or the pole mount installation you can also refer to these contents Figure 1 2 1 2 4 Address and Baud Rate Setup Now you can set the IR speed dome address and baud rate The IR speed dome interface is shown as below See Figure 1 3 There are ...

Page 11: ...IR speed dome device to the flange Please insert the cable socket to the corresponding slots according to the indication label See Figure 1 4 Figure 1 4 Speed Dome Installation Port Layout 1 Alarm input and output port 2 Video audio and RS485 port 3 Power port 4 Network port 4 3 2 1 ...

Page 12: ...ws firmly Otherwise it may result in low waterproof capability and speed dome malfunction Figure 1 5 1 3 Initial Setup The default setup is z Address 1 z Baud rate 9600 1 4 Dial Switch Setup The two dial switches of the speed dome are SW1 and SW2 These are to specify the speed dome parameter such as protocol baud rate address and etc When the button is ON it is 1 In the SW1 and SW2 1 is the lowest...

Page 13: ...3 4 5 6 7 8 ON 1 2 3 Communication Protocol OFF OFF OFF DH SD Compatible with China industrial standard protocol ON OFF OFF PELCO D OFF ON OFF PELCO P X X X Reserved Please refer to the baud rate sheet for detailed information 4 5 Baud Rate OFF OFF 9600bps ON OFF 4800bps OFF ON 2400bps ON ON 1200bps Please refer to the parity setup sheet for detailed information 6 7 Parity ...

Page 14: ...s 255 You can refer to the following sheet for more information Address 1 2 3 4 5 6 7 8 1 OFF OFF OFF OFF OFF OFF OFF OFF 1 ON OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF 7 ON ON ON OFF OFF OFF OFF OFF 8 OFF OFF OFF ON OFF OFF OFF OFF 254 OFF ON ON ON ON...

Page 15: ...wn as below See Figure 2 1 Ф58 G11 2 4 Ф9 84 119 110 145 235 Figure 2 1 2 2 Hanging mount bracket Multiple Lengths The hanging mount bracket is shown as below See Figure 2 2 Figure 2 2 The bracket length setup values are z 200mm z 300mm z 500mm You just need to replace the connection pole ...

Page 16: ...16 2 3 Corner mount bracket The corner mount bracket is shown as below See Figure 2 3 Figure 2 3 2 4 Pole mount bracket The corner mount bracket is shown as below See Figure 2 4 Figure 2 4 ...

Page 17: ...stallation please make sure The wall is thick enough to install the expansion bolt The wall can at least sustain the 4x weight of the speed dome 3 2 2 Installation Steps Please draw four holes position in the wall according to the hole of the bottom of the wall mount bracket Then you can dig four holes and insert the expansion bolts not provided Use four hex bolts and flat washer to fix the bracke...

Page 18: ...18 Figure 3 3 Please refer to chapter 1 2 for detailed installation information ...

Page 19: ...l the expansion bolt z The wall can at least sustain the 4x weight of the speed dome 4 2 2 Installation Steps Loosen the M4 bolt in the flange side to separate the flange and steeve Pull the integration cable through the airproof slot of the bottom of the flange and then connect to the centre hole of the flange Please secure the flange in the ceiling See Figure 4 3 Please note if the speed dome is...

Page 20: ... the silica gel on the steeve connection surface to do the waterproof work See Figure 4 4 Figure 4 4 Please draw four holes position in the wall according to the hole of the bottom of the wall mount bracket Then you can dig four holes and insert the expansion bolts not provided Use four hex but and flat washer to fix the bracket in the expansion bolts See Figure 4 5 Figure 4 5 Please refer to chap...

Page 21: ...ion bolt z The wall can at least sustain the 4x weight of the speed dome 5 2 2 Installation Steps Please draw four holes position in the wall according to the holes of the corner installation accessories See Figure 5 2 Figure 5 2 Then you can dig four holes and insert the M8 expansion bolts Pull the power cable video control cable and the alarm cable through the centre hole of the bottom of the co...

Page 22: ...22 Figure 5 3 Please refer to chapter 1 2 for detailed installation information ...

Page 23: ...h the installation dimension of the clamp Default factory clamp is six inches for the column of φ130 152mm It can work with the pole installation bracket You can adjust the diameter and the value clamp specification is φ59 82mm φ84 108mm φ103 127mm φ130 152mm φ155 178mm φ180 203mm φ194 216mm The clamp is shown as in Figure 6 2 Figure 6 2 For special dimensions please contact us for more informatio...

Page 24: ...ower cable through the hanging bracket and then fix the hanging bracket to the wall Please pay attention to the waterproof between the bracket and the wall See Figure 6 4 Figure 6 4 Please refer to chapter 1 2 for detailed installation information Clamp and pole bracket connection Pole bracket and the pole connection ...

Page 25: ...ne point to the earth Open floor cable layout is forbidden z In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install additional high power thunder protection device or lightning rod z The thunder protection and earth of the outdoor device and cable shall be considered in the building whole thunder protection and conform...

Page 26: ...e max transmission distance shall become longer 8 3 The Problem in Practical Use In practical usage we usually adopt star type connection The terminal resistance shall connect to the furthest two devices Such as device 1 and device 15 in Figure 8 1 But this connection way does not conform to RS485 Bus standard When the distances between devices are too long the signal reflection occurs and anti ja...

Page 27: ...s loose z RS485 Bus connection are cut off z Modify host or speed dome setup z Switch RS485 positive end and negative end z Fix connection cable firmly z Replace RS485 Bus I can control the speed dome but is not smooth z RS485 Bus connection are not good z One RS485 bus is off z The distance between host and speed dome is too far z Parallel connected too much speed domes z Connect RS 485 Bus again...

Page 28: ...000mm Feet m mm 0 8000 1 000 1 250 2 000 10 283 86 451 137 716 218 1811 551 20 141 42 225 68 358 109 905 275 30 94 28 150 45 238 72 603 183 40 70 21 112 34 179 54 452 137 50 56 17 90 27 143 43 362 110 60 47 14 75 22 119 36 301 91 70 40 12 64 19 102 31 258 78 80 35 10 56 17 89 27 226 68 90 31 9 50 15 79 24 201 61 100 28 8 45 13 71 21 181 55 110 25 7 41 12 65 19 164 49 120 23 7 37 11 59 17 150 45 13...

Page 29: ...8553 0 350 27 29 0 09621 0 400 26 28 0 1257 0 450 25 0 1602 0 560 24 24 0 2463 0 600 23 23 0 2827 0 710 22 22 0 3958 0 750 21 0 4417 0 800 20 21 0 5027 0 900 19 20 0 6362 1 000 18 19 0 7854 1 250 16 18 1 2266 1 500 15 1 7663 2 000 12 14 3 1420 2 500 4 9080 3 000 7 0683 Note This manual is for reference only Slight difference may be found in the user interface All the designs and software here are ...