•  With the nozzle removed, check that both chemicals flow with 

equivalent force.

•  Partial or complete blockage of one chemical port will result in 

off-ratio adhesive.

*Handi-Gun

®

 being shown for reference only.

Crunchy, friable, slow or non curing.  

Darker brown in color.

  “A-Rich” Adhesive:

Softer, white colored adhesive, with  

shrinkage.

  “B-Rich” Adhesive:

70

21

85

29

All Handi-Gun

®

 nozzles are easily cleanable and solvent resistant. To clean nozzles, 

liquid chemical must be dissolved prior to its complete chemical reaction by flushing the 

nozzle with Polysolv or other suitable solvent. Gun face can be kept clean with the use of 

petroleum jelly on the face or with a soft cloth to remove residue. Cleaning a nozzle more 

than twice is not recommended.

 Polysolv

Apply a small amount of petroleum jelly, 

which is provided with each kit, to help keep 

the gun face clean from cured adhesive or 

contamination that could block one of the 

chemical ports. Change nozzles frequently! 

Adhesive will cure inside the nozzle in the 

same amount of time that adhesive becomes 

tack-free in the air.

  Nozzle Care and Usage

   Temperature and Storage

Chemical temperature is very important, store kits at or above 

70°F (21°C) prior to use. Cold chemical may lead to off-ratio flow. 

Optimum chemical temperature is 70–85°F (21–29°C), see TDS for 

formula specific temperature recommendations.

A-component chemical may eventually 

harden and clog the hose if stored for 

too long. Gun is disposable and is not 

intended for continuous re-use. For best 

results, dispense liquid from hose at 

least once every 3 days. Use contents 

within 30 days of initial use.

Always read all operating, application and safety instructions before using any products from ICP Adhesives & Sealants, Inc. Use in conformance with all local, state and federal 

regulations and safety requirements. Failure to strictly adhere to any recommended procedures and reasonable safety precautions shall release ICP Adhesives & Sealants, Inc. of 

all liability with respect to the materials or the use thereof. For additional information and location of your nearest distributor, call ICP Adhesives & Sealants, Inc. 330.753.4585.

NOTE:

 Physical properties shown are typical and are to serve only as a guide for engineering design. Results are obtained from specimens under ideal conditions and may vary 

upon use, temperature and ambient conditions. Right to change physical properties as a result of technical progress is reserved. This information supersedes all previously 

published data.Yields shown are optimum and will vary slightly depending on ambient conditions and particular application. Read all product directions and safety information 

before use. This product is organic, and therefore, is combustible. Consult local building codes for specific requirements regarding the use of cellular plastics or urethane foam 

adhesive in construction.

 Important

WARNINGS:

 Polyset

®

 adhesive products are composed of a diisocyanate, hydrofluorocarbon blowing agent and polyol. Consult the product’s SDS (available at www.icpadhesives.

com) for specific information. The urethane foam adhesive produced from these ingredients will support combustion and may present a fire hazard if exposed to a fire or excessive 

heat about 240°F (116°C). Wear protective glasses with side shields or goggles, nitrile gloves, and clothing that protects against dermal exposure. Recommend using in a well 

ventilated area with certified respiratory protection or a powered air purifying respirator (PAPR). For more information regarding a certified respiratory program please visit 

http://www.cdc.gov/niosh/. To view or receive a copy of ICP Adhesives & Sealants, Inc.’s respirator program, please contact ICP Adhesives & Sealants, Inc. Customer Care at 

1.800.321.5585. Personal Protective Equipment can be purchased through ICP Adhesives & Sealants, Inc. distribution by purchasing the Polyset

®

 Contractor Safety Kit (F65251). 

The Contractor Safety Kit includes: nitrile gloves, contractor safety glasses, and a NIOSH approved negative pressure half mask respirator. For professional use only. WARNING: 

Non-Flammable Compressed Gas. Keep away from heat. Smoking and open flames, including hot work, should be prohibited in the vicinity of a foaming operation. Avoid contact 

with skin and eyes. May cause sensitiza- tion by inhalation and/or direct skin contact. Avoid prolonged or repeated breathing of vapor. 

KEEP OUT OF REACH OF CHILDREN. 

FIRST AID: 

In any first aid case CONSULT A PHYSICIAN. EYES: Flush with water for at least 15 minutes. SKIN: Remove contaminated clothing. Wash skin with plenty of soap and 

water. Cured adhesive must be removed manually. INHALATION: If breathing is difficult, give oxygen. If breathing has stopped, give artificial respiration. INGESTION: give large 

quantities of water. Do NOT induce vomiting. Contact a physician immediately in any first aid situation. Consult the product’s SDS (available at www.icpadhesives.com) for specific 

information. Contents: polymeric diisocyanate, hydrofluorocarbon blowing agent, polyol, amine catalyst.

 Warnings

The Manufacturer warrants only that the product shall meet its specifications: this warranty is in lieu of all other written or unwritten, expressed or implied warranties and The 

Manufacturer expressly disclaims any warranty of merchantability, or fitness for a particular purpose. The buyer assumes all risks whatsoever as to the use of the material. 

Buyer’s exclusive remedy as to any breach of warranty, negligence or other claim shall be limited to the replacement of the material. Failure to strictly adhere to any recommended 

procedures shall release the Manufacturer of all liability with respect to the materials of the use thereof. User of this product must determine suitability for any particular purpose, 

including, but not limited to, structural requirements, performance specifications and application requirements prior to installation and after product has been properly applied.

Limited Warranty

Polyset

®

 Spray Foam Adhesive products are composed of a diisocyanate, hydrofluorocarbon blowing agent and polyol. Consult the product’s SDS (available at www.icpadhesives.com) for specific 

information. The urethane foam adhesive produced from these ingredients will support combustion and may present a fire hazard if exposed to a fire or excessive heat about 240°F (116°C). Wear 

protective glasses or goggles, nitrile gloves, and clothing that protects against dermal exposure. Use only in a well ventilated area with certified respiratory protection or a powered air purifying respirator 

(PAPR). See SDS (available at www.icpadhesives.com) for specific information. For professional use only.

Summary of Contents for POLYSET CR-20

Page 1: ...POLYSET CR 20 POLYSET BOARD MAX COMMERCIAL ROOFING ADHESIVES OPERATING INSTRUCTIONS TWO COMPONENT DISPOSABLE KIT FOR PROFESSIONAL USE ONLY A16602 02 2017...

Page 2: ...hield the cylinders from direct sunlight and keep the product from getting too hot For this reason the box lid should remain closed during use For best results all surfaces to be bonded must be clean...

Page 3: ...hanges from clear to blue indicating that the chemical has reached a cold temperature below 60 F 16 C and the adhesive should not be dispensed Stop spraying and warm the chemical to the recommended te...

Page 4: ...of the spattered adhesive The seams of the membrane and the factory selvage edge must be protected from overspray of the Polyset CR 20 If overspray does contaminate the seam area immediately clean th...

Page 5: ...e the trigger and move hand at a speed which delivers the desired adhesive serpentine ribbon Polyset Board Max adhesive is applied in a serpentine ribbon placed at a maximum of 12 30 48 cm OC Insulati...

Page 6: ...er Personal Protective Equipment when disposing of cylinders 3 Dispense the adhesive into a waste container like a cardboard box or plastic bag Depressurize the used cylinders using the dispensing uni...

Page 7: ...excessive heat about 240 F 116 C Wear protective glasses with side shields or goggles nitrile gloves and clothing that protects against dermal exposure Recommend using in a well ventilated area with c...

Page 8: ...8...

Page 9: ...9 POLYSET CR 20 Y POLYSET BOARD MAX ADHESIVOS COMERCIALES PARA TECHOS INSTRUCCIONES DE FUNCIONAMIENTO EQUIPO DESECHABLE DE DOS COMPONENTES NICAMENTE PARA USO PROFESIONAL...

Page 10: ...la caja debe permanecer cerrada durante el uso Para obtener mejores resultados todas las superficies deben estar limpias secas y sin impurezas polvo aceite pintura suelta cera o grasa etc La temperatu...

Page 11: ...canzado temperaturas menores de 16 C 60 F y la espuma no se debe aplicar Detenga la aplicaci n y caliente la sustancia qu mica a la temperatura recomendada Consulte la ficha de datos t cnicos en cuant...

Page 12: ...sivo Polyset CR 20 Si el exceso contamina la zona de la costura limpiar inmediatamente la zona de costura con un limpiador o con Polysolv mientras el adhesivo CR 20 todav a est h medo El tiempo de adh...

Page 13: ...r inmediatamente sobre el adhesivo h medo pero no se deben aplanar ni comprimir en el adhesivo sino hasta que el adhesivo Polyset Board Max comience a espesar y a desarrollar su adherencia inicial El...

Page 14: ...cart n o bolsa de pl stico Despresurizar los tanques mediante el uso de la unidad de aplicaci n con una boquilla nueva Aplicar el adhesivo hasta que ya no salga sustancia qu mica de uno de los compone...

Page 15: ...ingredientes favorece la combusti n y puede representar un riesgo de incendio si se expone al fuego o a calor excesivo de unos 240 F 116 C Utilizar anteojos o gafas protectoras con protecci n lateral...

Page 16: ...16...

Page 17: ...17 POLYSET CR 20 POLYSET BOARD MAX ADH SIFS COMMERCIAUX DE TOITURE INSTRUCTIONS D UTILISATION KIT DE DEUX COMPOSANTS DISPONIBLES USAGE PROFESSIONNEL UNIQUEMENT...

Page 18: ...le produit d avoir une temp rature tr s lev e Pour cette raison le couvercle de la bo te doit rester ferm pendant l utilisation Pour obtenir de meilleurs r sultats toutes les surfaces coller doivent t...

Page 19: ...nt que le produit chimique a atteint une temp rature froide inf rieure 60 F 16 C et la mousse ne doit pas tre distribu e Arr tez la pulv risation et chauffez le produit chimique la temp rature recomma...

Page 20: ...cessive du Polyset CR 20 Si la pulv risation excessive ne contamine pas la zone de jointure nettoyez imm diatement la zone de jointure avec un nettoyant couture ou Polysolv lorsque le Polyset CR 20 es...

Page 21: ...sif humide mais ne doivent pas tre mis en place ou comprim s dans l adh sif jusqu ce que le Polyset Board Max commence devenir pais et commence d velopper sa liaison initiale Le temps n cessaire ce p...

Page 22: ...z l adh sif dans un conteneur d chets comme une bo te en carton ou un sac en plastique D pressurisez les r servoirs usag s l aide de l jecteur avec une nouvelle buse fix e Vaporisez l adh sif jusqu ce...

Page 23: ...ncendie ou une chaleur excessive d environ 240 F 116 C Porter des lunettes de protection avec des crans lat raux des gants en nitrile et des v tements de protection contre l exposition cutan e Utilisa...

Page 24: ...e only in a well ventilated area To ensure trouble free operations change nozzle after 30 seconds of non use Please read through the TDS SDS and Operating Instructions prior to use 1 2 MINUTES Safety...