ROCKY-3705EV-R2 Socket 370 Celeron
TM
, Pentium III
®
& Tualatin Processor with Ethernet , VGA , Audio Board
69
MEMORY SIZE HAS CHANGED SINCE LAST BOOT
Memory has been added or removed since the last boot. In EISA mode use
Configuration Utility to reconfigure the memory configuration. In ISA mode enter
Setup and enter the new memory size in the memory fields.
Memory Verify Error at ...
Indicates an error verifying a value already written to memory. Use the location
along with your system's memory map to locate the bad chip.
OFFENDING ADDRESS NOT FOUND
This message is used in conjunction with the I/O CHANNEL CHECK and RAM
PARITY ERROR messages when the segment that has caused the problem
cannot be isolated.
OFFENDING SEGMENT:
This message is used in conjunction with the I/O CHANNEL CHECK and RAM
PARITY ERROR messages when the segment that has caused the problem has
been isolated.
PRESS A KEY TO REBOOT
This will be displayed at the bottom screen when an error occurs that requires
you to reboot. Press any key and the system will reboot.
PRESS F1 TO DISABLE NMI, F2 TO REBOOT
When BIOS detects a Non-maskable Interrupt condition during boot, this will
allow you to disable the NMI and continue to boot, or you can reboot the system
with the NMI enabled.
RAM PARITY ERROR - CHECKING FOR SEGMENT ...
Indicates a parity error in Random Access Memory.
Should Be Empty But EISA Board Found
PLEASE RUN EISA CONFIGURATION UTILITY
A valid board ID was found in a slot that was configured as having no board ID.
NOTE; When this error appears, the system will boot in ISA
mode, which allows you to run the EISA Configuration Utility.
Should Have EISA Board But Not Found
PLEASE RUN EISA CONFIGURATION UTILITY
ROCKY-3705EV-R2 Socket 370 Celeron
TM
, Pentium III
®
& Tualatin Processor with Ethernet , VGA , Audio Board
70
The board installed is not responding to the ID request, or no board ID has been
found in the indicated slot.
NOTE: When this error appears, the system will boot in
ISA mode, which allows you to run the EISA Configuration
Utility.
Slot Not Empty
Indicates that a slot designated as empty by the EISA Configuration Utility
actually contains a board.
NOTE: When this error appears, the system will boot in ISA
mode, which allows you to run the EISA Configuration Utility.
SYSTEM HALTED, (CTRL-ALT-DEL) TO REBOOT ...
Indicates the present boot attempt has been aborted and the system must be
rebooted. Press and hold down the CTRL and ALT keys and press DEL.
Wrong Board In Slot
PLEASE RUN EISA CONFIGURATION UTILITY
The board ID does not match the ID stored in the EISA non-volatile memory.
NOTE: When this error appears, the system will boot in ISA
mode, which allows you to run the EISA Configuration Utility.
FLOPPY DISK(S) fail (80)
→
Unable to reset floppy subsystem.
FLOPPY DISK(S) fail (40)
→
Floppy Type dismatch.
Hard Disk(s) fail (80)
→
HDD reset failed
Hard Disk(s) fail (40)
→
HDD controller diagnostics failed.
Hard Disk(s) fail (20)
→
HDD initialization error.
Hard Disk(s) fail (10)
→
Unable to recalibrate fixed disk.