Step 8: Use the Ladder Designer to program the logic – the second rung.
a.
Similar to Step 7. Move the cursor to an empty position and then press the F6 button
to add a new rung with a function block.
b.
Move the cursor to the previously-created function block and then press the F7 button
to create a new function block to the right of the first one.
c.
Double-click on the first function block to set its function to “GE” (greater than or
equal to) of the category, “default”.
d.
Double-click on the second function block to set its function to “Assign” of the
category, “default”.
e.
Set the value of the parameter “in2” of the function “GE” (>=) by double-clicking on
the neighborhood of the parameter “in2”.
f.
To enter a constant to a parameter, click on the tab “Enter Constant” in the “Select
variable” window. Here we enter 10.
g.
Similarly, set the parameter “in” of the function “Assign” to zero.
h.
Similarly, select “count” to parameter “in1” of the function “GE” (>=).
i.
Similarly, select “count” to the parameter “out” of the function “Assign”.