background image

ICP DAS Co., LTD 

PM-3133i Quick Start V1.00 

Page 1 

PM-3133i Quick Start 

1.  Shipping Package 

This shipping package contains the following items

 

 

1 x PM-3133i module    1 x Quick Start      Screw Driver x 1    Cable ties x 3 

 

 

1.1. Caution & Warning 

The meter contains hazardous voltages, and should 

never be disassembled. Failing to follow this practice will 

result in serious injury or death. Any work on or near energized meters, 

meter sockets, or other metering equipment could induce a danger of 

electrical shock. It is strongly recommended that all work should be 

performed only by qualified industrial electricians and metering 

specialist. ICP DAS assumes no responsibility if your electrical installer 

does not follow the appropriate national and local electrical codes. 

ICP DAS assumes no liability for any damage resulting from the use of 

this product. ICP DAS reserves the right to change this manual at any 

time without notice. The information furnished by ICP DAS is believed 

to be accurate and reliable. However, no responsibility is assumed by 

ICP DAS for its use, not for any infringements of patents or other rights 

of third parties resulting from its use. 

Summary of Contents for PM-3133i

Page 1: ...r of electrical shock It is strongly recommended that all work should be performed only by qualified industrial electricians and metering specialist ICP DAS assumes no responsibility if your electrica...

Page 2: ...ility http ftp icpdas com pub cd powermeter pm 3133i 1 2 1 Limitation of Warranty This warranty does not apply to defects resulting from unauthorized modification misuse or use for reason other than e...

Page 3: ...hed CT s can be used The other CT s for example from panel will damage the instrument due to its large current around 5A or mA 3 When more than one smart meter PM 3133i series are installed please do...

Page 4: ...ing the terminal lines Otherwise it will cause severe injury 6 Please handle with extra care especially when the operation space of CT s is limited 7 The current direction must follow K L marked on CT...

Page 5: ...Start V1 00 Page 5 2 4 CT s installation steps At the bottom of the CT there is a K L mark Open the CT clip Make sure the power current direction follow the K L mark on the CT and then close the CT cl...

Page 6: ...ICP DAS Co LTD PM 3133i Quick Start V1 00 Page 6 2 5 Wiring 1P2W 1CT PM 3133i 1P3W 2CT PM 3133i...

Page 7: ...ICP DAS Co LTD PM 3133i Quick Start V1 00 Page 7 3P3W 3CT PM 3133i 3P4W 3CT PM 3133i...

Page 8: ...F ON OFF OFF OFF 7 OFF ON ON OFF OFF OFF 8 ON ON ON OFF OFF OFF 9 OFF OFF OFF ON OFF OFF 10 ON OFF OFF ON OFF OFF SW7 SW8 For Baud Rate Setting RS 485 CAN SW 7 SW8 9600 bps 125k Default OFF OFF 19200...

Reviews: