background image

 

M-4132 Quick Start User Guide (Version 1.10 Oct/2009)                      

  

  PAGE: 2  

7-pin screw terminal block 

Pin Name 

Description 

T.GND 

GND of trigger input 

2 Trig 

Trigger 

input 

D+ 

Data+ of RS-485 

D- 

Data- of RS-485 

PWR 

V+ of Power Supply (+10 to +30VDC) 

GND 

GND of Power Supply 

7 F.G. 

Frame 

Ground 

 

DIP Switch and Trigger button 

 

Dip switch and trigger button for initial function 

Option State 

Description 

Recover default 
setting forever 

SW2=ON 
SW1=ON 
To press the TB about 40 
second after power on 

All system settings will be cleared and 
recover default settings. 
(Warning: it will not restore settings 
after clear) 

IP recover default 
setting for this time 

SW2= OFF 
SW1= ON 
To press the TB about 40 
second after power on 

After power on, it will set IP to default 
setting (192.168.1.217) for this time, 
but it will restore original IP at next 
time.  

IP recover default 
setting forever 

SW2= ON 
SW1= OFF 
To press the TB about 40 
second after power on 

After power on, it will set IP to default 
setting (192.168.1.217) and save to 
flash. 

Display the current IP 
and version 

SW2=OFF 
SW1=OFF 

After power on, it will display the 
message about current IP and version 

Summary of Contents for M-4132

Page 1: ...n CD ROM Path CD napdos multimedia m 4132 manual m 4132 user manual pdf for detail The manual is intended to help users quickly understanding and easily using of M 4132 We use two M 4132s one as Serve...

Page 2: ...nd after power on All system settings will be cleared and recover default settings Warning it will not restore settings after clear IP recover default setting for this time SW2 OFF SW1 ON To press the...

Page 3: ...is initial ok and wait client to login Client The Ethernet is initial ok and login completely It has readied to enable voice and com port data connection SA2 flash fast It is sending or receiving voic...

Page 4: ...is finished else M 4132s IPs will conflict The connection setting will be described below and Microsoft Windows XP Professional SP2 is used a Setting the Network of PC Set the IP and Subnet mask of th...

Page 5: ...r Guide Version 1 10 Oct 2009 PAGE 5 Step 3 Click Properties button Step 4 Click Properties button Step 5 Set Internet Protocol Properties b connection test Step 1 Click start Run Step 2 key in cmd an...

Page 6: ...68 1 217 bytes 32 time 1ms TTL 64 Reply from 192 168 1 217 bytes 32 time 1ms TTL 64 Reply from 192 168 1 217 bytes 32 time 1ms TTL 64 Reply from 192 168 1 217 bytes 32 time 1ms TTL 64 Ping statistics...

Page 7: ...d SA2 flash slowly one minute later it means the Server and Client work normally and ready to use e Error check If these LEDs statuses are not the same as the above check the power supply network conn...

Page 8: ...st of Login list Please select Client1 in the drop down list of Login list and click Pair Connection button The SA2 of the Server and Client will flash quickly it means the voice connection is establi...

Reviews: