background image

 

M-4132 Quick Start User Guide (Version 1.10 Oct/2009)                      

  

  PAGE: 3  

Option State 

Description 

To press the TB about 40 
second after power on 

information from Com Port(RS-232). 

Normal setting 

The other states 

Normal state; It will not change any 
setting and data. 

 

LED Indicator 

 

LED status indicator 

Name Status 

Description 

on 

Power supply is ok. 

PWR 

off

 

Power supply has failed.

 

SA1 

flash 

It is receiving com port data via Ethernet.   

flash slowly 

Server: The Ethernet is initial ok and wait client to login.   
 
Client: The Ethernet is initial ok and login completely. It has 
readied to enable voice and com port data connection.   

SA2 

flash fast

 

It is sending or receiving voice data via Ethernet. 

 

on 

AP has some errors. (Client: Please check settings about IP & 
DNS)

 

flash slowly (SA1 
& SA2 flash at the 
same time)

 

It is trying to establish the connection with server/client. If it 
can’t connect to server/client for a long time, please check it has 
available network settings and is working well on Ethernet. 

 

SA1 

SA2 

flash (SA1 & SA2 
alternate flash)

 

Server: Receive the request to connect from the client. 
Client: Request the server to connect. 

 

 

 

Summary of Contents for M-4132

Page 1: ...n CD ROM Path CD napdos multimedia m 4132 manual m 4132 user manual pdf for detail The manual is intended to help users quickly understanding and easily using of M 4132 We use two M 4132s one as Serve...

Page 2: ...nd after power on All system settings will be cleared and recover default settings Warning it will not restore settings after clear IP recover default setting for this time SW2 OFF SW1 ON To press the...

Page 3: ...is initial ok and wait client to login Client The Ethernet is initial ok and login completely It has readied to enable voice and com port data connection SA2 flash fast It is sending or receiving voic...

Page 4: ...is finished else M 4132s IPs will conflict The connection setting will be described below and Microsoft Windows XP Professional SP2 is used a Setting the Network of PC Set the IP and Subnet mask of th...

Page 5: ...r Guide Version 1 10 Oct 2009 PAGE 5 Step 3 Click Properties button Step 4 Click Properties button Step 5 Set Internet Protocol Properties b connection test Step 1 Click start Run Step 2 key in cmd an...

Page 6: ...68 1 217 bytes 32 time 1ms TTL 64 Reply from 192 168 1 217 bytes 32 time 1ms TTL 64 Reply from 192 168 1 217 bytes 32 time 1ms TTL 64 Reply from 192 168 1 217 bytes 32 time 1ms TTL 64 Ping statistics...

Page 7: ...d SA2 flash slowly one minute later it means the Server and Client work normally and ready to use e Error check If these LEDs statuses are not the same as the above check the power supply network conn...

Page 8: ...st of Login list Please select Client1 in the drop down list of Login list and click Pair Connection button The SA2 of the Server and Client will flash quickly it means the voice connection is establi...

Reviews: