background image

TOUCh YOUR LOGO OR WeLCOMe sCReen anYWheRe TO COnTinUe
The Main OPeRaTinG sCReen WiLL nOW aPPeaR.

The 

Main OPeRaTinG sCReen

 provides many options which are covered elsewhere in this manual, however 

to quickly start the system you can simply accept the default water temperature setting of 15ºC or,  to select a 

different temperature touch the 

ChanGe seTTinGs

 button. Then 10ºC will be inserted automatically, but you 

can change to any temperature you require at this point. simply touch the up and down arrow buttons and the 

desired pool water temperature will appear on the bottom left-

hand  of  the  screen  in  the  blue  window  marked    “seLeCTeD 

TeMPeRaTURe”.  The right-hand side of the screen shows the 

outside air temperature. 

The  temperatures  is  in  degrees  centigrade,  however  it  can 

also be displayed in Fahrenheit. This is explained later in this 

Manual.

Once you have selected the pool water temperature you want 

your iCool to cool to, touch the 

sTaRT

 button. This takes you 

back to the main run screen which is the screen that you will 

use most of the time during normal operation. 

sTeP 5

Touch  the 

sTaRT

 

PUMP

  button.  This  will  start  the  pump 

operating and water should begin circulating. 

nOTe! When you touch sTaRT buttons they change to sTOP 

buttons and can then be used to sTOP that function if required.

iT is essenTiaL ThaT The WaTeR is FLOWinG CORReCTLY 
BeFORe YOU TOUCh The 

sTaRT sYsTeM 

BUTTOn.

 

The water flow is pre set to an optimum flow of about 15-20 

litres or around 3-5 gallons per minute. This allows time for the 

heat exchanger to operate at maximum cooling efficiency. 
Pool water is completely changed approximately every 15 to 20 

minutes.
Do not touch the 

sTaRT sYsTeM

 button until you are sure that water is flowing smoothly. if water does not 

flow smoothly within a minute or so, please check that the hose with the pump  is flat on the floor and no part 

of it is higher than the top of the water. Check that the water in the pool is higher than the pump. if this does 

not correct the problem the system will sound an alarm and a red warning screen will appear with information 

about how to correct the water flow problem. 

sTeP 6

now that you have pre set your desired temperature and started the circulating pump, notice that the pump 

button will have changed from 

sTaRT

 to 

sTOP

. You can use this same button to start and stop the pump at  

any time.
now, touch the 

sTaRT sYsTeM

 button and the cooling cycle will begin. The water will be cooled to your preset 

temperature and the system will then cycle to maintain it at that temperature automatically. 

The sYsTeM can 

only be started once within any 3 minute period to avoid overloading the compressor. so if you don’t hear it 

start do not touch the sTaRT sYsTeM again , it will start automatically after the 3 minutes safety period elapses.

if you ordered a personal logo screen your WeLCOMe screen will look like the samples below. Otherwise the 

standard iCool welcome screen will appear

 WaTeR  TeMPeRaTURe seTTinG sCReen

sTaRT

sTaRT

sTaRT

sTaRT

sTaRT

sTaRT

10

22

22

30

15

24

 

Main OPeRaTinG sCReen

Summary of Contents for iCool Compact Series

Page 1: ...Owner s Manual for Compact Range Compact Range Models Compact Cool Compact Twin Compact Dual Temp Compact XP...

Page 2: ...to the main power socket TO ensURe saFe OPeRaTiOn The POWeR OUTLeT YOU Use MUsT have a PROPeR eaRTh COnneCTiOn BUiLT in saFeTY sYsTeMs Your iCool system has many safety features to protect against su...

Page 3: ...e FOR eaCh seT UP Once primed of air the system will remain primed and water will normally flow instantly each time you start the pump until the pool is emptied or the iCool is moved neveR OPeRaTe The...

Page 4: ...nt snap fittings that are very quick and easy to use Your 2014 model features an new type of pump that is very small and relaible it has on board intelligence it will surge automatically for a few sec...

Page 5: ...er switch to shut down instantly after a sUCCessFUL test reset the main switch to On to begin normal operation sTeP 4 YOUR sYsTeM sOFTWaRe WiLL BeGin LOaDinG Your iCool has a full colour high resoluti...

Page 6: ...optimum flow of about 15 20 litres or around 3 5 gallons per minute This allows time for the heat exchanger to operate at maximum cooling efficiency Pool water is completely changed approximately eve...

Page 7: ...that your iCool is now heating it will continue to heat until it reaches your pre set temperature and then hold that temperature for as long as you wish YOU MUsT Use a POOL COveR When heaTinG The WaT...

Page 8: ...e TeMPeRaTURe WinDOW shows the current room or outside temperature it is not desirable to operate this system in temperatures above 42 C or 108 F if the reading exceeds this you need to move the syste...

Page 9: ...aRe aUTOMaTiCaLLY seLeCTeD so there is usually no need to use this feature The three settings you can change are the fan speed range the temperature from degrees Centigrade to Fahrenheit and the soun...

Page 10: ...Ge seTTinG BUTTOn and this will take you to the WaTeR TeMPeRaTURe seTTinG sCReen illustrated above right where you can use the up and down arrows to select the temperature you require after you make y...

Page 11: ...ctly The session timer is set up from the main TiMe seTTinG sCReen by touching the seT COUnTDOWn button The numbers on the setting screen in the bottom right hand corner will begin to flash and you ca...

Page 12: ...o effect if you re particular iCool model does not have a sound system built in To activate the sound system touch the sOUnD button This takes you to a simple sound control screen that turns the ampli...

Page 13: ...M TO PRevenT TaMPeRinG YOUR iCOOL has an eLeCTROniC LOCK as you can see iCool systems have attractive user interfaces this makes them easy and very intuitive to use but the downside is that untrained...

Page 14: ...n the screen automatically if this happens it must be remembered of course that if you disarm this system the pump is no longer protected from running dry without water lubrication so it is essential...

Page 15: ...9 5x9 5 24x19 5x9 5 24x19 5x9 5 24x19 5x9 5 For safety reasons you can only initiate the heating mode at the time the unit is first switched on You can not change to heating while you are using it in...

Page 16: ...the iCool Compact For all other iCools simply plug the filter pump to a normal wall power outlet in either case you will still need to touch the start Pump button before touching the start system butt...