![icontrols PULSE Installation Manual And Setup/User Instructions Download Page 3](http://html.mh-extra.com/html/icontrols/pulse/pulse_installation-manual-and-setup-user-instructions_613428003.webp)
2
3
GENERAL OVERVIEW
Thank you for purchasing this Pulse Direct Drive Door operator. This dependable operator is
designed for continuous-cycle duty for your Commercial Door and can extend the life of your
counter-balanced sectional door with its integrated soft-start/soft-stop capability.
It also features adjustable opening speeds of up to approximately 24” per second, battery
backup that can operate the door in case of power failure, over-current protection, and
adjustable auto-reversing force monitoring, along with many other programmable functions.
MEETING UL 325:2017 REQUIREMENTS
The Pulse Operator is provided with a Polarized Reflective Photo-Eye or Thru-Beam Photo-Eye (1
& 2HP model only), which is connected into Terminal 1 of the ‘Reversing Devices’ input on the
Control Panel. Once the Close button is activated, the operator verifies that the Photo-Eye is
connected and functional, and it continues to monitor the sensor as the door closes.
A dedicated terminal (Terminal 2 Reversing Devices) is provided to operate with Monitored
Reversing Devices.
Input (Terminal 3 Reversing Devices) for non-monitored reversing devices (i.e. standard
pneumatic edge).
The Pulse Operator will initiate Push/Hold to CLOSE protocols should devices in Terminal 1 and
2 be found non-functional, misaligned or unconnected (at least one functional device must be
connected and verified in either Terminal 1 or Terminal 2). Note that during Push/Hold to Close
protocols, the door will reverse should it not fully reach the closed limit per UL 325.
BOX INVENTORY
Before beginning installation, please verify that all components are accounted for:
1. Motor, Gearbox, Encoder, Junction Box Assembly
2. Control Panel
3. Limit Brackets and Hardware (Angle Brackets for Stop Limit to mount on door tracks)
4. Torque Arm, Mounting Bolts, Mounting Bracket
5. Shaft Collar and Shaft Key
6. Reversing Device – Reflective Photo-eye (Thru-Beam Photo-Eye included on Pulse 1000/2000)
7. Two 12V, Lead-Acid Rechargeable Batteries (3 Batteries fo Pulse 2000)
In case any of the above items is missing, please contact iControls and provide us with details of
the missing part(s), as well as the serial number of your operator.
OPERATOR TECHNICAL OVERVIEW
Motor
HORSEPOWER:
Pulse500 = ½ HP Pulse750 = ¾ HP Pulse1000 = 1 HP Pulse 2000 = 2 HP
SPEED:
1750 RPM
CURRENT (FLA):
½ HP = 5A
¾ HP = 7.6A
1 HP = 10A
2 HP = 10A(208-240Vac)
OUTPUT TORQUE: Pulse500 =
54Nm,
Service Factor 1.6
Pulse750-1 =
80Nm,
Service Factor 1.1
Pulse750-1.25 = 108Nm,
Service Factor 2.0
Pulse1000 =
147Nm,
Service Factor 1.5
Pulse
2000
=
Summary of Contents for PULSE
Page 7: ...7 TORQUE ARM POSITION IN RELATION TO OPERATOR ...
Page 13: ...13 WIRING DIAGRAMS ...
Page 14: ...14 ...
Page 15: ...15 ...
Page 16: ...16 ...
Page 17: ...17 ...
Page 26: ...26 PULSE OPERATOR COMPONENTS ...