OUTPUT RELAY OPTIONS
The Output Relay is used for signalling/interlocking with other devices such as a
dock leveller, security equipment, other doors, etc. There is one NO and one NC
contact available that can be energized at either the open or closed limit, as
chosen by the user in this setting.
The Factory setting for this feature is ENERGIZED WHEN OPEN.
CALIBRATION
This feature is required to calibrate load-sensing. Screen prompts guide user
through calibration.
NOTE: IF YOU CHANGE ANY OF THE FOLLOWING SETTINGS, THE
OPERATOR WILL PROMPT YOU TO RECALIBRATE WHEN EXITING THE
MENU:
Voltage Range, Motor position, Door Limits, Open Speed, Close Speed,
PWM Frequency, Open Rampdown and Close Rampdown.
CALIBRATION Cont'd...
THE CALIBRATION OF THE DOOR INVOLVES THE FOLLOWING STEPS:
- An automatic slow opening cycle of the door. (You will be prompted to open
the door)
- A manual close cycle of the door. Press and Hold the CLOSE button through
this cycle. If the CLOSE button isn't held until door is fully closed, the Operator
will abort this step and prompt you to start again.
- You will be prompted to open the door to Calibrate Opening Force.
- Resetting the Encoder. Once the door is fully open, you will have to press
OPEN again to reset the Encoder (The LCD screen will say
"DOOR IS READY"
as a prompt before the Encoder is to be reset.)
MAINTENANCE SCHEDULE
This feature sets a reminder, displayed on the LCD, to schedule maintenance
after a selected number of operator cycles. Factory default is set to notify of
Maintenance after 250,000 cycles (recommended for Motor Brush Replacement).
It can be lowered in 1,000 cycle increments. Press the OPEN or CLOSE buttons to
change, and Press and Hold the buttons for rapid scrolling to your required cycle
setting.
RED FLASHING
Set this feature to ON if you prefer the red light of an attached LED Stop & Go Light
to flash while the door is in motion.
ADVANCED RED
Used in conjuction with the CLOSING TIMER (Page 18), this safety feature turns on
the red light (or flashing red light if this setting has been enabled) of an attached
LED Stop & GO light in advance of the door closing by a programmed number of
seconds. Note that should you choose a value that is greater than the CLOSING
TIMER pre-set, it will begin at the same time. Factory Default is the 'OFF' setting,
with options for 1-9 seconds of ADVANCED RED.