SETTING DOOR SPEEDS
On initial set up please use the factory default MEDIUM speed. As noted below the Motor, Door
and Drum size may affect the opening speed of the door and the Medium setting may be all that
is required to achieve 24” per second opening speed. Test door at factory setting prior to setting
adjustment.
Please note that the Pulse has been developed with the same technology that is used in High Speed Door Operators.
While we have limited the maximum opening speed to ~24” per second for sectional doors (this is dependent on
the type of door and drum used) and maximum closing speed to ~16” per second, we recommend that you set the
speed to accommodate both your requirement, and the hardware of the door. To get the longest life out of your door,
and to maximize your allowable speed, we recommend Stainless Steel cables and nylon rollers be installed if they
are not already standard on your door.
OPENING SPEED
To access the Open Speed Settings, ensure you are in STARTUP MENU (see above
instructions), then toggle between options using the OPEN or CLOSE buttons until
Open Speed appears on the screen. Then press the STOP button to access and
macke changes.
The Pulse operator is factory equipped with 3 options of open speed settings:
low, medium and high. Toggle between these 3 options by using the OPEN and/
or CLOSE buttons, and press the Stop button once the desired selection appears
on the screen to save and return to the STARTUP menu.
CLOSING SPEED
To access the Closing Speed Settings, ensure you are in STARTUP MENU (see
above instructions), then toggle between options using the OPEN or CLOSE
buttons until Close Speed appears on the screen. Then press the STOP button to
select.
he Pulse operator is factory equipped with 3 options of close speed settings: low,
medium and high. Toggle between these 3 options by using the OPEN and/or
CLOSE buttons, and press the Stop button once the desired selection appears on
the screen to save and return to the STARTUP menu.
CLOSING FORCE
If the door is obstructed from closing (ie. due to obstruction, jam, etc.) this current
monitoring feature will stop and reverse the door to prevent damage. The
sensitivity of this monitoring can be changed in this setting, or the feature can be
turned off entirely.
Closing Force sensitivity can be adjusted from 1-99 (1 being most sensitive to
obstructions/jams/imbalance) or OFF. Factory default is ‘30’.
Note that if this setting is turned to OFF, Push & Hold to Close protocol (constant pressure) will be initiated.
OPENING FORCE
If the door is obstructed from opening (ie. due to ice buildup, the door latch
is engaged, etc.) this current monitoring feature will stop the door to prevent
damage. The sensitivity of this monitoring can be changed in this setting, or the
feature can be turned off entirely.
Opening Force sensitivity can be adjusted from 1-99 (1 being most sensitive to
obstructions/jams/imbalance) or OFF. Factory default is ‘99’.