STARTUP MENU - ACCESSING ALL MENU SELECTIONS
NOTE THAT ALL FACTORY MENU SETTINGS ARE RECOMMENDED FOR
SECTIONAL DOORS ONLY. CONTACT iCONTROLS FOR SETTINGS FOR OTHER DOOR STYLES (i.e. Rolling Steel, etc.)
For access to the STARTUP MENU press and hold the STOP button on the control
board (bottom button beside the LCD screen) for 5 Seconds - do not release
until STARTUP MENU appears on the screen. Once done, you can scroll between
the various STARTUP MENU options by pressing the OPEN and CLOSE buttons.
Once you have reached a selection that you would like to change, press the
STOP button. Use the OPEN and CLOSE buttons to scroll/toggle between options
within the selection, and then press STOP to save your selection and return to the
STARTUP MENU.
CLOSING TIMER
IT IS NOT RECOMMENDED TO SET THE CLOSING TIMER UNTIL AFTER THE UNIT HAS BEEN
FULLY TESTED.
The Closing Timer will automatically close the door after opening by the preset
number of seconds that have been programmed using this STARTUP MENU option.
Once you have accessed this option, use the OPEN and CLOSE buttons to
increase or decrease the closing timer value in 1 second intervals. If it is not
required, ensure that the Closing Timer is set to OFF. If it is required, set it to any
number of seconds from 1 to 99. Remember that this is the number of seconds
that the door will remain open before automatically closing. Press the STOP
button to save the value and return to the SETUP MENU.
The Closing Timer will de-activate in the event that the Photo-Eye is in a fault
condition (blocked, misaligned, damaged), and manual Push and Hold to Close
protocols (constant pressure) will apply to door closing operations.
DOOR LIMITS
NOTE: PROGRAMMING OF LIMITS SHOULD BE PERFORMED BY TRAINED
PERSONNEL ONLY. THE ENCODER WILL RETAIN THESE LIMITS UNLESS RE-
PROGRAMMED.
Press the STOP button to set the limits. Once selected, DOOR LIMITS heading will
appear with a prompt to ‘Push OPEN to Start'. Push the OPEN button, and the door
will open to the fully open position against the Limit Brackets. ENSURE THAT THE TOP
ROLLERS OF THE DOOR ARE RESTING AGAINST THE LIMIT BRACKETS. The Open Limit
now needs to be set.
SET OPEN LIMIT
Press CLOSE (OPEN functional should you overshoot desired position) to jog
the door to the desired Open Limit height.
The Open Limit Setting Should be a
minimum offset of 3" from the Limit Bracket
. Press STOP button to save Open
Limit and advance to SET CLOSE LIMIT.
SET CLOSE LIMIT
From the Open Limit, jog to the desired Close position, using the CLOSE button
(OPEN available for fine tuning). Ensure that the door is properly sealed at the
bottom.
Press STOP button to save and return to STARTUP MENU.