Introduction

The 

LevelPro

®

  300S

  Continuous  Submersible  Level  Transmitter  and  tank  level  junction  box  are  a  perfect  pair  for  applications  where 

ultrasonic sensors aren’t going to work.

Accurately  measure  tank  levels  with  this  rugged  combination  that’s  simple  to  use  and  boasts  superior  chemical  resistance  along  with 
industry exclusive features.

www.iconprocon.com | [email protected] | 905.469.9283

03

Continuous Submersible Level Sensor

300S Series

R

Indicates a potential hazard. Failure to follow all 
warnings may lead to equipment damage, injury, or 
death

Warning | Caution | Danger

Use of tool(s) may damage product beyond repair 
and potentially void product warranty.

Do Not Use Tools

Highlights additional information or detailed 
procedure.

Note | Technical Notes

Safety Information

indicates situations or cases which, if not avoided, 
could result in damage or failure of the 

Products

 

equipment.

IMPORTANT! 

General Information

This  operating  manual  contains  important  information  on  proper  usage  of  the  device.  Read  this  operating  manual  carefully  before 
installing and starting up the pressure measuring device.

Adhere  to  the  safety  notes  and  operating  instructions  which  are  given  in  the  operating  manual.  Additionally  applicable  regulations 
regarding  occupational  safety,  accident  preven-tion  as  well  as  national  installation  standards  and  engineer-ing  rules  must  be  complied 
with!

This operating manual is part of the device, and should be kept nearest its location, always accessible to all employees.

This  operating  manual  is  copyrighted. The  contents  of  this  operating  manual  reflect  the  version  available  at  the  time  of  printing.  It  has 
been issued to our best knowledge. 

Levelpro 

is not liable for any incorrect statements and their effects.

Limitation of Liability

By non observance of the operating manual, inappropriate use, modification or damage, no liability is assumed and warranty claims will be excluded.

Intended Use

The 

LevelPro

®

 300S

 Level Sensors have been developed for continuous level measurement. It is the operator's responsibility to check 

and verify the suitability of the device for the intended application. If any doubts remain, please contact our technical department in order 
to ensure proper usage and compatibility. 

LevelPro

®

 is not liable for any incorrect selections and their effects!

Permissible media are liquids (no solids or frozen media), specified in the data sheet. In addition it has to be ensured, that this medium is 
compatible with the any wetted parts of the level sensor.

The  technical  data  listed  in  the  current  data  sheet  are  engaging  and  must  be  complied  with.  If  the  data  sheet  is  not  available,  please 
order or download it from our homepage. 

(www.iconprocon.com)

Package Contents

Please verify that all listed parts are undamaged included in the delivery and check for consistency specified in your order:

Probe
Mounting Instructions

316 SS — Superior Chemical/Corrosion Resistance
Teflon

®

 Jacketed Cable

Kalrez

®

 (FFKM) O-Ring Seal

Works on Foam | Vapor | Turbulence | Condensate
No Floating
IP68 | NEMA 4X Enclosure

Summary of Contents for Levelpro 300S Series

Page 1: ...Submersible Level Sensors 300S Series Operating Manual Continuous Submersible Level Sensor 300S Series R www iconprocon com sales iconprocon com 905 469 9283 Diesel DEF Chemicals R...

Page 2: ...250B Display Connection Diagram Sensor TVL Display Connection Diagram Sensor Sentinel LTE TVL Display Understanding Level Measurement Application Details Getting Started Calculating Max Range of Sens...

Page 3: ...evice and should be kept nearest its location always accessible to all employees This operating manual is copyrighted The contents of this operating manual reflect the version available at the time of...

Page 4: ...after mainte nance work the probe has to be submerged slowly into the medium A rough immersion into the medium can damage or destroy the diaphragm If there is any danger of damage by lightning or ove...

Page 5: ...K 0 1 Full Scale Over One Year Response Time 10 msec Thermal Effects Offset and Span Permissible Temperatures Electrical Protection Thermal Drift 0 02 FSO K in Compensated Range 13 F 178 F 25 C 85 C S...

Page 6: ...re After Features New Vaporbloc Technology NEMA 4X Enclosure Tool Free Wiring Terminals All Plastic NEMA 4X Enclosure 2 Threaded Connection Excellent Chemical Resistance Weather Resistant Gortex Air B...

Page 7: ...Technology for Outdoor Applications No Assembly Required 8 Levels of Brightness Signal Peak Value Detection Dampens Noise 3 Wire Cord Grips Included No Add Ons Relay Lights Audible Alarm Function Comp...

Page 8: ...hrough Cable Gland Remove Heat Shrink Discard Heat Shrink Remove Filter from Vent Tube Feed Wires through VaporBloc Ensure VaporBloc is Oriented Correctly Sensor Junction Box Installation www iconproc...

Page 9: ...rBloc Installed Take Junction Box Open Lid Open Lid Fuming Liquids Please Install VaporBloc 1 Feed Sensor Red and Black Wire Breather into Junction Box 2 Tighten Cord Grip 1 4 Turn Lid is Tethered Do...

Page 10: ...Tighten Only Connection Diagram Sensor 250B Display 300S Series Level Sensor Supply Supply Vs Red Black Sensor Wire Red Terminal 1 Black Terminal 3 Red Terminal 2 Black Terminal 4 300S Series Sensor 1...

Page 11: ...ay 4 20 Output Examples Pump Shut Off Valve Shut Off Wiring to a Loop Powered Display 300S Series Level Sensors 1 2 3 4 5 6 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Power Supply 120VAC Terminal 1 2 TVL...

Page 12: ...2 3 4 5 6 Junction Box Terminals Green wire Terminal 5 Black wire Terminal 4 Junction Box Terminals Red wire Terminal 3 Black wire Terminal 2 13 12 11 10 09 08 07 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6...

Page 13: ...he Tank Empty 4mA setting 2 Full The Pressure being exerted on the sensor s diaphragm at the highest point Liquid Level within the Tank Full 20mA setting 3 Chemical Concentration Specific Gravity Temp...

Page 14: ...e sensor range changes when submersed into liquids with different Specific Gravities Please note that the physical location of the level transmitter will indicate the lowest level of measurement withi...

Page 15: ...he sensor has increased and is now 64 or 816 The liquid in Tank 2 has a S G 2 which is 2X Heavier than H20 The 34 sensor is now going to be installed into a tank to measure a liquid with a S G 2 Range...

Page 16: ...inated at a LP100 junction box located on top of the tank Since the vent tube is contained within the cable the pressure within the junction box A Gortex Breather to ensure accurate atmospheric pressu...

Page 17: ...be is fitted with a Gortex Filter this must remain attached in order to prevent moisture particulate or insects from entering Do Not Remove Avoid blocking or bending the ventilation tube The LP100 Ins...

Page 18: ...cal mechanical or chemical damage due to improper accidental or negligent use 3 Have been modified or altered 4 Anyone other than service personnel authorized by Icon have attempted to repair 5 have b...