ICON Levelpro 300S Series Operating Manual Download Page 18

Icon Process Controls

 warrants to the original  purchaser of its products that such products will be free from defects in materials and 

workmanship  under  normal  use  and  service  in  accordance  with  instructions  furnished  by 

Icon  Process  Controls

  for  a  period  of  one 

years from the date of sale of such products. 

Icon Process Controls

 obligation under this warranty is solely and exclusively limited to 

the  repair  or  replacement,  at  Icon's  option,  of  the  products  or  components,  which  Icon  examination  determines  to  its  satisfaction  to  be 
defective in material or workmanship within the warranty period. 

Icon Process Controls

 must be notified within thirty (30) days pursuant 

to  the  instructions  below  of  any  claims  of  lack  of  conformity  under  this  warranty.  Any  product  repaired  under  this  warranty  will  be 
warranted  only  for  the  remainder  of  the  original  warranty  period.  Any  product  provided  as  a  replacement  under  this  warranty  will  be 
warranted for the full 1 year from the data of sale.

Warranty

Products  cannot  be  returned  to 

Icon  Process  Controls

  without  Icon's  prior  authorization.  To  return  a  product  that  is  thought  to  be 

defective please submit a customer return (MRA) request form and follow the instructions therein. All warranty and non-warranty product returns 
to 

Icon Process Controls

 must be shipped prepaid and insured. Icon will not be responsible for any products lost or damaged in shipment.

Returns

This warranty does not apply to products which:

1) Are beyond the warranty period or are products for which the original purchaser does not follow the warranty procedures outlined above;
2) Have been subjected to electrical, mechanical or chemical damage due to improper, accidental or negligent use;
3) Have been modified or altered;
4) Anyone other than service personnel authorized by Icon have attempted to repair;
5) have been involved in accidents or natural disasters;
6) Are damaged during return shipment to 

Icon Process Controls

.

Icon Process Controls reserves the right to unilaterally waive this warranty and dispose of any product returned to Icon where :

1) There is evidence of a potentially hazardous material present with the product;
2) The product has remained unclaimed at 

Levelpro

 for more than 30 days after 

Icon Process Controls

 has dutifully requested disposition.

This  warranty  contains  the  sole  express  warranty  made  by  Levelpro  in  connection  with  its  products.  ALL  IMPLIED  WARRANTIES, 
INCLUDING  WITHOUT  LIMITATION,  THE  WARRANTIES  OF  MERCHANTABILITY  AND  FITNESS  FOR  A  PARTICULARPURPOSE, 
ARE EXPRESSLY DISCLAIMED. The remedies of repair or replacement as stated above are the exclusive remedies forthe breach of this 
warranty.  IN  NO  EVENT  SHALL  LEVELPRO  BE  LIABLE  FOR  ANY  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGESOF  ANY  KIND 
INCLUDING  PERSONAL  OR  REAL  PROPERTY  OF  FOR  INJURY TO ANY  PERSON. THIS  WARRANTYCONSTITURES THE  FINAL, 
COMPLETE  AND  EXCLUSIVE  STATEMENT  OFWARRANTY  TERMS  AND  NO  PERSON  IS  AUTHORIZED  TO  MAKE  ANY  OTHER 
WARRANTIES OR REPRESENTATIONS ONBEHALF OF 

Icon Process Controls

.

If  any  portion  of  this  warranty  is  held  to  be  invalid  or  unenforceable  for  any  reason,  such  finding  will  not  invalidate  any  other 
provision of this warranty

For  additional  product  documentation  and  technical  support 

visit  www.iconprocon.com  |  e-mail:  [email protected]   

[email protected] | Ph: 905.469.9283

Limitations

Warranty, Returns & Limitations

www.iconprocon.com | [email protected] | 905.469.9283

18

Continuous Submersible Level Transmitter

R

300S Series

Summary of Contents for Levelpro 300S Series

Page 1: ...Submersible Level Sensors 300S Series Operating Manual Continuous Submersible Level Sensor 300S Series R www iconprocon com sales iconprocon com 905 469 9283 Diesel DEF Chemicals R...

Page 2: ...250B Display Connection Diagram Sensor TVL Display Connection Diagram Sensor Sentinel LTE TVL Display Understanding Level Measurement Application Details Getting Started Calculating Max Range of Sens...

Page 3: ...evice and should be kept nearest its location always accessible to all employees This operating manual is copyrighted The contents of this operating manual reflect the version available at the time of...

Page 4: ...after mainte nance work the probe has to be submerged slowly into the medium A rough immersion into the medium can damage or destroy the diaphragm If there is any danger of damage by lightning or ove...

Page 5: ...K 0 1 Full Scale Over One Year Response Time 10 msec Thermal Effects Offset and Span Permissible Temperatures Electrical Protection Thermal Drift 0 02 FSO K in Compensated Range 13 F 178 F 25 C 85 C S...

Page 6: ...re After Features New Vaporbloc Technology NEMA 4X Enclosure Tool Free Wiring Terminals All Plastic NEMA 4X Enclosure 2 Threaded Connection Excellent Chemical Resistance Weather Resistant Gortex Air B...

Page 7: ...Technology for Outdoor Applications No Assembly Required 8 Levels of Brightness Signal Peak Value Detection Dampens Noise 3 Wire Cord Grips Included No Add Ons Relay Lights Audible Alarm Function Comp...

Page 8: ...hrough Cable Gland Remove Heat Shrink Discard Heat Shrink Remove Filter from Vent Tube Feed Wires through VaporBloc Ensure VaporBloc is Oriented Correctly Sensor Junction Box Installation www iconproc...

Page 9: ...rBloc Installed Take Junction Box Open Lid Open Lid Fuming Liquids Please Install VaporBloc 1 Feed Sensor Red and Black Wire Breather into Junction Box 2 Tighten Cord Grip 1 4 Turn Lid is Tethered Do...

Page 10: ...Tighten Only Connection Diagram Sensor 250B Display 300S Series Level Sensor Supply Supply Vs Red Black Sensor Wire Red Terminal 1 Black Terminal 3 Red Terminal 2 Black Terminal 4 300S Series Sensor 1...

Page 11: ...ay 4 20 Output Examples Pump Shut Off Valve Shut Off Wiring to a Loop Powered Display 300S Series Level Sensors 1 2 3 4 5 6 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Power Supply 120VAC Terminal 1 2 TVL...

Page 12: ...2 3 4 5 6 Junction Box Terminals Green wire Terminal 5 Black wire Terminal 4 Junction Box Terminals Red wire Terminal 3 Black wire Terminal 2 13 12 11 10 09 08 07 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6...

Page 13: ...he Tank Empty 4mA setting 2 Full The Pressure being exerted on the sensor s diaphragm at the highest point Liquid Level within the Tank Full 20mA setting 3 Chemical Concentration Specific Gravity Temp...

Page 14: ...e sensor range changes when submersed into liquids with different Specific Gravities Please note that the physical location of the level transmitter will indicate the lowest level of measurement withi...

Page 15: ...he sensor has increased and is now 64 or 816 The liquid in Tank 2 has a S G 2 which is 2X Heavier than H20 The 34 sensor is now going to be installed into a tank to measure a liquid with a S G 2 Range...

Page 16: ...inated at a LP100 junction box located on top of the tank Since the vent tube is contained within the cable the pressure within the junction box A Gortex Breather to ensure accurate atmospheric pressu...

Page 17: ...be is fitted with a Gortex Filter this must remain attached in order to prevent moisture particulate or insects from entering Do Not Remove Avoid blocking or bending the ventilation tube The LP100 Ins...

Page 18: ...cal mechanical or chemical damage due to improper accidental or negligent use 3 Have been modified or altered 4 Anyone other than service personnel authorized by Icon have attempted to repair 5 have b...

Page 19: ......

Reviews: