background image

 

 

11 

If a product does not operate as warranted during the applicable warranty period, Icoms Detections shall, at its 
option, either repair the defective unit, or deliver an equivalent product or part to replace the defective item. All 
products that are replaced become property of Icoms Detections. 

The defective product must be returned to Icoms Detections within the applicable warranty period. The defective 
product must be shipped DDP (delivered duty paid) back to Icoms Detections, wrapped in the original or similar 
shipping package to ensure that it will not be damaged during transportation. It must be accompanied by 
appropriate paperwork (ask first for a 

R

eturn 

M

aterial 

A

uthorisation number) detailing the nature of the defect 

experienced. 

Icoms Detections shall be under no liability in respect of any defect arising from normal wear and tear, wilful 
damage, negligence, damage due to inappropriate packaging, abnormal working conditions, failure to follow Icoms 
Detections instructions (whether oral or in writing), misuse,  improper installation, alteration or repair without 
Icoms Detections approval. 

DECOMMISSIONING 

We encourage customers to send back decommissioned equipment to the manufacturer for recycling. To 
differentiate between equipment to be recycled and equipment to be repaired, please inform your reseller or the 
manufacturer about the decommissioned equipment. 

Icoms Detections will take care of the recycling for a sustainable end-of-life of the product. 

FURTHER INFORMATION 

L

EGAL NOTIFICATION

 

Hereby, Icoms Detections declares that this TMA range of products is in compliance with the requirements and 
other relevant provisions of  

 

Directive 2014/53/EC. 

 

FCC Part 15B Class A 

 

IC ICES-003 issue 6 

V

ERSION

 

Issue n° 

Date 

Comment 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

        

 

 

 

    

 

 

V 1.1 

02 May 2019 

First release 

V 1.3 

03 June 2019 

Update on encoder settings 

V 1.4 

15 July 2019 

Update on detection distance 

V 1.5 

07 Nov 2019 

Update on power supply and heating option 

V 1.6 

31 Aug. 2020 

Update relay cabling 

V 1.7 

08 Mar. 2021 

Layout update – Temperature 

V 1.7.2 

27 May 2021 

Update on test and normal mode and “do not connect” connector pins 

V 1.7.3 

April 5, 2022 

Update on wire colours for molded cable 

V 1.7.4 

May 19, 2022 

Update 250 V relay 

V 1.7.5 

October 19, 2022 

Added “Decommissioning” section 

V 1.7.6 

January 27, 2023 

Layout 

T

HE MANUFACTURER

 

 

Icoms Detections S.A. 
Avenue Albert Einstein 11/B 

 B-1348 Louvain-la-Neuve 

 BELGIUM 

Tel.: +32 (0) 10 45 41 02 

 Fax: +32 (0) 10 45 04 61 

[email protected] 

 www.icomsdetections.com 

 

Summary of Contents for TMA-011

Page 1: ...TION 4 2 1 IDENTIFICATION LABEL 4 2 2 SERIAL NUMBER 4 3 SETTINGS 4 SAFETY PRECAUTIONS 5 CABLING 6 DESCRIPTION OF PARAMETERS 7 1 SELF MONITORING 7 2 RF CHANNEL 7 3 DETECTION DISTANCE 7 4 DETECTION DIRE...

Page 2: ...CONNECTOR WEIPU SP1712 P9 6 FIGURE 6 TMA 011 HV RADAR CONNECTOR WEIPU SP2112 P7 6 FIGURE 5 TMA 011 LV AND MV RADAR CONNECTOR WEIPU SP1712 P9 8 FIGURE 6 TMA 011 HV RADAR CONNECTOR WEIPU SP2112 P7 8 FIG...

Page 3: ...nd check the following items are in the box A Radar with rear side socket B Sticker for front face C Cable with connector D Mounting bracket E User s guide and tune up procedure 2 Set the encoders acc...

Page 4: ...ket See tune up procedure for more details Figure 1 delivery 2 LABELS LOCATION 2 1 IDENTIFICATIONLABEL 2 2 SERIALNUMBER 3 SETTINGS You can set different parameters through 2 encoders allowing 16 posit...

Page 5: ...ust be made whilst the power supply is switched off Ensure the wiring is correct as shown in the manual before switching on the power supply Never use a damaged radar or cable Opening the outer casing...

Page 6: ...ot connect USER S OUTPUTS Resistive load 30 V AC 0 3 A 60 V DC 0 3 A Option 250 V relay 250 V AC 30 V DC 0 3 A REMARKS Make sure the plug is fully inserted in the socket and the cap is firmly tightene...

Page 7: ...rocedure for further information 2 RF CHANNEL This parameter allows to shift the radar s frequency If two units face each other they must be put on different channels as to not interfere with each oth...

Page 8: ...3 4 5 6 7 8 9 A B C D E F Detection distance 8 12 16 30 m Factory setting 0 2 ENCODER 2 Besides green LED at the right facing the housing Encoder position 0 1 2 3 4 5 6 7 8 9 A B C D E F Uni bi direct...

Page 9: ...nimum of 750 milliseconds 2 WHEN THE SELF MONITORING DETECTS AN ERROR The two LEDs blink quickly 2 or 4 quick flashes followed by a 1 sec break depending on the detected error INSTALLATION GUIDE 1 GEN...

Page 10: ...4V AC 50 60 Hz 21 75V DC 100V 240V AC 50 60 Hz Power consumption 12V DC 1 2 W 220V AC 2 W User output Inverted relay contact Resistive load 30V AC 0 3 A 60V DC 0 3 A Option 250 V relay 250 V AC 30 V D...

Page 11: ...to send back decommissioned equipment to the manufacturer for recycling To differentiate between equipment to be recycled and equipment to be repaired please inform your reseller or the manufacturer a...