6
Figure 2: TMA-011 LV and
MV radar connector - Weipu
SP1712/P9
Figure 3: TMA-011 HV
radar connector - Weipu
SP2112/P7
CABLING
CAUTION: positive security/fail safe relays - contacts given for powered radar.
HV
(100-240 VAC)
PIN nr
Color
Function
1
BLUE
~ Power Supply
2
BROWN
~ Power Supply
3
YELLOW
/GREEN
EARTH
4
WHITE
Relay - COM
5
GREY
Relay - NO
6
YELLOW
Relay - NC
7
PURPLE
Do not connect
USER’S OUTPUTS
Resistive load: 30 V AC 0.3 A - 60 V DC 0.3 A
Option 250 V relay: 250 V AC - 30 V DC – 0.3 A
REMARKS
•
Make sure the plug is fully inserted in the socket and the cap is firmly tightened on the socket.
•
Please disconnect the radar from power before maintenance intervention.
LV
(12-60 VDC – 10-30 VAC)
& MV
(21-75 VDC – 15-54 VAC)
PIN nr
Color
Function
1
RED
Power ~ (AC), + (DC)
2
BLUE
Do not connect
3
BLACK
Power ~(AC), - (DC GND)
4
BROWN
Do not connect
5
WHITE or
PURPLE
Relay - COM
6
GREY
Relay - NO
7
YELLOW
Relay - NC
8
GREEN
Do not connect
t
9
PINK
or
ORANGE
Do not connect