background image

 

 

10 

3.

 

Place the radar on the top of the traffic light, aiming the on-
crossing: 

4.

 

Firmly tighten the screws. 

 

D

ETECTION ZONE

 

 

Figure 10: Detection zone at 0.5m distance from the pavement, H = 3,5m, 10°tilt angle, detection distance 16 m. 

 

This drawing shows the theoretical radar lobe and does not consider environmental variables. This drawing is for 
indication purpose only. 

TECHNICAL FEATURES 

 

TMA-011-LV 

TMA-011-MV 

TMA-011-HV 

Protection level 

IP 65 

Power supply 

10-30V AC, 50-60 Hz 

12V-60V DC 

15-54V AC, 50-60 Hz 

21-75V DC 

100V –240V AC, 50-60 Hz 

Power consumption 

@12V DC: < 1.2 W 

@220V AC: < 2 W 

User output 

 

Inverted relay contact - Resistive load: 30V AC 0.3 A – 60V DC 0.3 A 

 

Option 250 V relay: 250 V AC - 30 V DC – 0.3 A 

 

2 LED outputs on front face 

Temperature range 

-40° C to +60° C 

Dimensions 

68 mm x 99 mm x 119 mm 

68 mm x 99 mm x 180 mm 

Weight 

350 g 

460 g 

485 g 

Wiring & connectors 

Weipu connector 

WARRANTY 

Icoms Detections warrants its hardware products to be free from defects in workmanship and materials, under 
normal use and service, for a period of two (2) years from the date of dispatch from Icoms Detections premises, 
except for the batteries for which a warranty period of six (6) months applies. 

Summary of Contents for TMA-011

Page 1: ...TION 4 2 1 IDENTIFICATION LABEL 4 2 2 SERIAL NUMBER 4 3 SETTINGS 4 SAFETY PRECAUTIONS 5 CABLING 6 DESCRIPTION OF PARAMETERS 7 1 SELF MONITORING 7 2 RF CHANNEL 7 3 DETECTION DISTANCE 7 4 DETECTION DIRE...

Page 2: ...CONNECTOR WEIPU SP1712 P9 6 FIGURE 6 TMA 011 HV RADAR CONNECTOR WEIPU SP2112 P7 6 FIGURE 5 TMA 011 LV AND MV RADAR CONNECTOR WEIPU SP1712 P9 8 FIGURE 6 TMA 011 HV RADAR CONNECTOR WEIPU SP2112 P7 8 FIG...

Page 3: ...nd check the following items are in the box A Radar with rear side socket B Sticker for front face C Cable with connector D Mounting bracket E User s guide and tune up procedure 2 Set the encoders acc...

Page 4: ...ket See tune up procedure for more details Figure 1 delivery 2 LABELS LOCATION 2 1 IDENTIFICATIONLABEL 2 2 SERIALNUMBER 3 SETTINGS You can set different parameters through 2 encoders allowing 16 posit...

Page 5: ...ust be made whilst the power supply is switched off Ensure the wiring is correct as shown in the manual before switching on the power supply Never use a damaged radar or cable Opening the outer casing...

Page 6: ...ot connect USER S OUTPUTS Resistive load 30 V AC 0 3 A 60 V DC 0 3 A Option 250 V relay 250 V AC 30 V DC 0 3 A REMARKS Make sure the plug is fully inserted in the socket and the cap is firmly tightene...

Page 7: ...rocedure for further information 2 RF CHANNEL This parameter allows to shift the radar s frequency If two units face each other they must be put on different channels as to not interfere with each oth...

Page 8: ...3 4 5 6 7 8 9 A B C D E F Detection distance 8 12 16 30 m Factory setting 0 2 ENCODER 2 Besides green LED at the right facing the housing Encoder position 0 1 2 3 4 5 6 7 8 9 A B C D E F Uni bi direct...

Page 9: ...nimum of 750 milliseconds 2 WHEN THE SELF MONITORING DETECTS AN ERROR The two LEDs blink quickly 2 or 4 quick flashes followed by a 1 sec break depending on the detected error INSTALLATION GUIDE 1 GEN...

Page 10: ...4V AC 50 60 Hz 21 75V DC 100V 240V AC 50 60 Hz Power consumption 12V DC 1 2 W 220V AC 2 W User output Inverted relay contact Resistive load 30V AC 0 3 A 60V DC 0 3 A Option 250 V relay 250 V AC 30 V D...

Page 11: ...to send back decommissioned equipment to the manufacturer for recycling To differentiate between equipment to be recycled and equipment to be repaired please inform your reseller or the manufacturer a...

Reviews: