![Icom id- rp2 Instruction Manual Download Page 19](http://html1.mh-extra.com/html/icom/id-rp2/id-rp2_instruction-manual_3596544019.webp)
16
4
INSTALLING AND CONNECTING
2001 NEW
ID-RP2L installation
■
R
DANGER!
The ID-RP2L installation is in-
tended for professional installation only. We are not
responsible for any building breakage, any damage
resulting from dropping the ID-RP2L from a high
place or unstable site or resulting from any personal
injury or any accident under any circumstances. Be
sure to consult an expert engineer for installations.
The ID-RP2L must be directly connected to the para-
bolic antenna element.
The element cable extension may cause communica-
tion error, therefore the ID-RP2L must be installed right
under the parabolic antenna.
U-bolt
Pole clamp
Flat washer
Spring
washer
Nut
ID-RP2L
q
Install the ID-RP2L onto the pole, right under the
parabolic antenna, using with the supplied U-bolts,
pole clamps, flat washers, spring washers and
nuts.
NOTE:
The ID-RP2L must be installed where the
place without obstacle to the parabolic antenna
beam adjustment.
Rubber vulcanizing
tape (purchase
separately)
*Wrap from under on.
Fix with an adhesive tape
w
Connect the antenna element to the ID-RP2L [ANT]
connector.
e
Fix the antenna element cable to the element arm
with slacks for both element and the ID-RP2L sides
using with vinyl tape or cable fastener, etc.
NOTE:
Cover the antenna connector with rubber
vulcanizing tape to protect the antenna connec-
tor from water intrusion.
*Wrap the rubber vulcanizing tape from the under on.
Summary of Contents for id- rp2
Page 1: ...DIGITAL REPEATER SYSTEM id rp2 Instruction Manual...
Page 54: ...51 MEMO...
Page 55: ...52 MEMO...