MDC 1200 SYSTEM OPERATION

MDC 1200 system operation

The MDC 1200 signaling system enhances your transceiver’s 
capabilities. You can receive or transmit PTT ID and Emer-
gency  calls.  You  can  also  receive  Radio  Check,  Stun,  and 
Revive calls.

An additional feature of the MDC 1200 system included in 
Icom transceivers is called aliasing. Each transceiver on the 
system has a unique ID number. Aliasing is a substitute for 
this ID number and 

you can set a ringer for each station ID. 

When  you  receive  a  call  from  the  specific  transceiver,  you 

can distinguish it by its ringer type.

Please confirm that your dealer has set one of the program-
mable keys for MDC 1200 system operation. See page 

4

 for 

more information about the programmable function keys.

Receiving a call

Receiving a PTT ID

 

D

 When a PTT ID is received:

 

q

 Beeps sound.

w

 Hold down 

[PTT] and speak into the microphone.

e

 Release 

[PTT] to receive a response.

D

 Receiving an Emergency Call

q

 When an emergency call is received:

Beeps sound.

w

  When the Send Ack function is turned ON, the transceiver 

automatically transmits an acknowledgement to the calling 
station.

e

  Turn power OFF or change the channel to stop the beep 

and the display indication.

D

 Receiving a Stun or Revive Call

If  a  Stun  call  is  received  that  matches  your  station  ID,  you

 

can  not  receive  or  transmit.  If  a  Revive  call  that  matches 
your station ID is received, the transceiver will be revived.

Summary of Contents for IC-V10MR

Page 1: ...OPERATING GUIDE VHF TRANSCEIVER IC V10MR...

Page 2: ...r SAVE THIS OPERATING GUIDE This operating guide contains important oper ating instructions for IC V10MR TRANSCEIVER Icom Icom Inc and the Icom logo are registered trademarks of Icom Incor porated Jap...

Page 3: ...on 6 Receiving and transmitting 6 Emergency Call 8 Lone Worker Emergency Call 9 Man Down Emergency Call 9 Motion Detection Emergency Call 9 User set mode 10 Setting the microphone gain 10 Setting the...

Page 4: ...turn the power ON or OFF and to adjust the audio level e DEALER ASSIGNABLE KEY Emer A desired function can be programmed by your dealer 1 1 PANEL DESCRIPTION w VOLUME CONTROL VOL e Emer Speaker r SPE...

Page 5: ...d by your dealer i ANTENNA CONNECTOR Hold down to transmit release to receive LED INDICATOR Lights red while transmitting Lights green while receiving a signal or when the squelch is open Lights or bl...

Page 6: ...urning ON the power Calling Audible Lockout TX Inh TOT when transmit is inhibited Successful Failed Error Emergency Siren G G G G G G G G R G R G R G R G R G R G R G R G R O R O R O R O R O R O R O R...

Page 7: ...to select the Priority A or Priority B channel PRIORITY A CHANNEL REWRITE PRIORITY B CHANNEL REWRITE Push to select the Priority A or Priority B channel Hold down Prio A Rewrite or Prio B Rewrite to...

Page 8: ...nce or repeat edly depending on the presetting Hold down during the Emer SW OFF timer period to can cel the Emergency function before transmitting an Emer gency call SURVEILLANCE Hold down to turn ON...

Page 9: ...eceiving and transmitting CAUTION Attach an antenna before transmitting Transmitting without an antenna may damage the trans ceiver Receiving Rotate q q VOL to turn ON the power Rotate w w ROTARY SELE...

Page 10: ...n is cut off Penalty timer The time out timer cuts off transmission further transmis sion is inhibited for the preprogrammed penalty timer peri od DReceiving a Stun Kill and Revive call The dispatcher...

Page 11: ...ansmitting the call If your transceiver is programmed for Silent operation you can transmit an Emergency call without the beep sounding and the LED indicator lighting IMPORTANT It is recommended to se...

Page 12: ...ntal position for a set time period the transceiver enters the emergency mode and then a countdown starts After a set time period has passed an emergency call is au tomatically transmitted once or rep...

Page 13: ...he current level setting by the increas ing loudness of the beep that sounds Rotate t t VOL to turn OFF the power then ON again to exit the microphone gain adjustment mode NOTE This operation may not...

Page 14: ...quelch level tight squelch or push Lower to decrease the squelch level loose squelch The adjustable range is 0 loose squelch to 9 tight squelch A beep sounds after pushing Upper or Lower An error beep...

Page 15: ...the level If the level is at 5 pushing Upper selects the linked levels starting with 1 Linked If the level is at 1 Linked to 4 Linked pushing Upper increases the level If the level is at 5 Linked pus...

Page 16: ...er increas es the level and pushing Lower decreases the level If the level is at 5 Linked pushing Upper returns the level to 1 Repeat edly pushing Upper or Lower repeats the cycle A beep sounds after...

Page 17: ...firm that your dealer has set one of the program mable keys for MDC 1200 system operation See page 4 for more information about the programmable function keys Receiving a call Receiving a PTT ID D D W...

Page 18: ...the operating channel When the Repeat Cancel function is ON the transceiver cancels repeating after receiving an acknowledgement When the Repeat Cancel function is OFF the transceiver repeats calling...

Page 19: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan A 7122 3EX 2020 Icom Inc...

Reviews: