background image

4

2

BIIS 1200 OPERATION

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

D

 Receiving a Group call

q

 When a Group call is received:

  • Rings sound.
  • “

 

 

” appears and the mute is released.

  •  “

 

 

” appears or blinks, depending on the pre-programmed set-

tings.

  •  The group ID (or name) and the calling station’s ID (or name) 

blink.

w

  While holding down 

[PTT], speak into the microphone at 

your normal voice level.

 

NOTE:  Only  one  station  is  allowed  to  speak  at  the 
same time.

e

 Release 

[PTT] to receive.

 After the communication is finished, push 

[Moni (Audi)] to 

send a ‘Clear down’ signal to terminate the connection. 

  • Either station can send a ‘Clear down’ signal.
  •  “

 

 

” disappears, “

CLR DOWN” appears for approximately 2 sec-

onds, and the transceiver automatically returns to the stand-by 
mode. 

D

 Receiving an Emergency call

q

 When an Emergency call is received:

  • Rings sound.
  • “

Emergency” and the calling station’s ID (or name) blink.

  •  The transceiver automatically transmits an acknowledgement to 

the calling station.

w

 Push 

[Moni (Audi)] to return to the stand-by mode.

BIIS CALL TXCE CLR

1234

4001

4001

1111

TXCE

CALL BIIS

TXC

Group ID

Calling station ID

Appears

Appears or 
blinks

Calling station’s ID

Group ID

Appears Appears or blinks

BIIS CALL TXCE MON

1234

Calling station’s ID

 

Emergency

 

Summary of Contents for IC-F4160DS

Page 1: ...OPERATING GUIDE OPERATING GUIDE FOR IC F3162DT DS IC F4160DT DS BIIS 1200 dPMR OPERATION...

Page 2: ...is guide con tains important oper ating instructions for IC F3162DT DS vhf dpmr mobile transceiver IC F4162DT DS uhf dpmr mobile transceiver NOTE In this operating guide the LCD illustration is shown...

Page 3: ...3 BIIS display 3 Receiving a call 3 Transmitting a call 7 Position data transmission 11 Stun function 11 BIIS ANI 11 Printer connection 12 3 dPMR OPERATION 13 27 dPMR operation 13 dPMR display 13 Rece...

Page 4: ...d to toggle between the memory channel mode and the queue channel mode While in the queue channel mode push to toggle between the queue channel mode and the received message mode D For only dPMR opera...

Page 5: ...status messages and SDM are selectable in the same mode D Additional key functions For both BIIS 1200 and dPMR operations The following key functions are recommended for BIIS 1200 and dPMR operations...

Page 6: ...all is re ceived WAIT While transmitting CLR DOWN When a connection is terminated BUSY When the operating channel is busy Receiving a call D Receiving an Individual call q When an Individual call is r...

Page 7: ...communication is finished push Moni Audi to send a Clear down signal to terminate the connection Either station can send a Clear down signal disappears CLR DOWN appears for approximately 2 sec onds a...

Page 8: ...s alternately displayed In that case push Status Down to display the status message manually D Receiving an SDM q When an SDM is received Rings sound The calling station s ID or name and the SDM blink...

Page 9: ...ll using the selected ID D Displaying a received message The transceiver memorizes up to six received messages When the seventh message is received the oldest mes sage will be removed and the last rec...

Page 10: ...one Ask your dealer for details D Transmitting an Individual or Group call NOTE If you want to make a call to the pre programmed ID skip step q and w then directly go to step e q Push BIIS Button to...

Page 11: ...annel is always used to send status mes sages q Push BIIS Button to enter the call code memory mode appears The pre programmed ID is displayed w Push CH Up or CH Down to select a desired Individual ID...

Page 12: ...rn to the stand by mode D Direct message input Only 10 key version While displaying an SDM you can edit or change the mes sage q Push BIIS Button twice to enter the message selection mode then push CH...

Page 13: ...ends the transceiver automatically starts an Emergency call cycle once or repeatedly de pending on the pre programmed repeat cycle setting e In an Emergency call cycle the transceiver automatically tr...

Page 14: ...anDown item to Enable By the Automatic Position Data Transmission function When the function is activated the transceiver auto matically transmits position data according to the Time Marker and Interv...

Page 15: ...r connection When a printer is connected to the transceiver through the OPC 966 interface cable received SDM and the calling station s ID can be printed out depending on the pre pro grammed settings A...

Page 16: ...hen a connection is terminated ID When no name is programmed appears to the left of the calling station s ID TG When no name is programmed appears to the left of the Talkgroup ID Receiving a call D Re...

Page 17: ...k at the same time eRelease PTT to receive r After the communication is finished push Clear to send a Disconnect signal to terminate the connection Either station can send a Disconnect signal disappea...

Page 18: ...the call will be ignored and the transceiver will not be stunned killed or revived When a Stun command is received the transceiver is disa bled 1 In that case receiving a Revive command or input ting...

Page 19: ...digital signal the Talk Back function is activated for Voice and Emergency calls and depending on the pre programmed settings also for status messages and SDM When the channel type is Mixed Digital Af...

Page 20: ...ect CALL LOG e Push dPMR Button again to display a call log entry r Push CH Up or CH Down to display a desired entry If a Status or SDM call log entry is selected not only the calling station s ID but...

Page 21: ...to store the setting The transceiver returns to the stand by mode NOTE Changing the channel or turning OFF the trans ceiver discards the new ID and returns the original one When no acknowledgement is...

Page 22: ...ar to send a Disconnect signal to terminate the connection Either station can send a Disconnect signal D Transmitting a Status Polling Call The transceiver can send a signal that causes the target sta...

Page 23: ...MR Button again to enter the application selec tion mode STATUS is displayed r Push dPMR Button again to enter the status message selection mode The pre programmed status message is displayed t Push C...

Page 24: ...tion mode STATUS is displayed r Push CH Up or CH Down to select MESSAGE t Push dPMR Button again to enter the SDM selection mode The pre programmed SDM is displayed y Push CH Up or CH Down to select a...

Page 25: ...characters u Push to move the cursor to the right push M to move the cursor to the left i Repeat steps y and u to enter a message of up to 100 characters o Hold down dPMR Button for 1 second to write...

Page 26: ...nce or repeatedly de pending on the pre programmed repeat cycle setting e In an Emergency call cycle the transceiver automatically transmits a digital signal to inform the dispatcher that the user is...

Page 27: ...IT is displayed while transmitting OK is displayed when an acknowledgement is received then the called station s microphone audio can be heard for the pre programmed time period FAILED is displayed wh...

Page 28: ...wledgment is received y After a specified time period the transceiver will return to the stand by mode D Transmitting a Revive Call A Revive call allows you to send a command that will revive the stun...

Page 29: ...et the Send with Emergency item to Enable After sending an Emergency call with the Man Down function Set the Send at ManDown item to Enable By the Automatic Position Transmission function When the fun...

Page 30: ...inter is connected to the transceiver through the OPC 966 interface cable received SDM and the calling station s ID can be printed out depending on the pre pro grammed settings Ask your dealer or syst...

Page 31: ...MEMO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16...

Page 32: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan A 6842 2EU 2010 Icom Inc...

Reviews: