5 - 11
5-11 RECEIVE SENSITIVITY ADJUSTMENT
(continued)
1) Select an adjustment item (band) using
[2]
/
[8]
.
2) Set the SSG as specifi ed (frequency, deviation and output level).
3) Push the
[BAND]
to adjust (automatic) and store the adjustment value.
ADJUSTMENT
ADJUSTMENT
ITEM
OPERATION
VALUE
[469.9 MHz*]
[Tr]
20 • Set the SSG as;
Frequency
: 469.9 MHz
Level
: –3 dBµ (–110 dBm)
†
Push
[BAND].
(Automatic
adjustment)
[470.1 MHz*]
21 • Set the SSG as;
Frequency
: 470.1 MHz
Level
: 0 dBµ (–107 dBm)
†
[535.1 MHz*]
22 • Set the SSG as;
Frequency
: 535.1 MHz
Level
: 0 dBµ (–107 dBm)
†
[599.9 MHz*]
23 • Set the SSG as;
Frequency
: 599.9 MHz
Level
: 0 dBµ (–107 dBm)
†
[600.1 MHz*]
24 • Set the SSG as;
Frequency
: 600.1 MHz
Level
: 0 dBµ (–107 dBm)
†
[780.1 MHz*]
25 • Set the SSG as;
Frequency
: 780.1 MHz
Level
: 0 dBµ (–107 dBm)
†
[999.9 MHz*]
26 • Set the SSG as;
Frequency
: 999.9 MHz
Level
: 0 dBµ (–107 dBm)
†
†
; This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.
*; This frequency is an example only, and may differ from the actual frequency displayed on the function display.