Installation Manual

Premier Elite 32XPH-W

INS732

Summary of Contents for Premier Elite 32XPH-W

Page 1: ...Installation Manual Premier Elite 32XPH W INS732...

Page 2: ...0 V2 09 24 48 88 168 640 Ricochet V2 xx 9 Introduction 9 Deleting Devices 10 Device Modes of Operation 10 Zone Types Attributes 11 Standalone Mode 12 Standalone Operation 12 This table shows two examp...

Page 3: ...iability with each device already aware of the number of communication paths available to it Firmware versions prior to those listed are NOT compatible Control Panel Premier Elite 32XPH W Legacy Ricoc...

Page 4: ...l of the devices have been learnt they will need placing in their desired location this should be done by installing devices closest to the expander first and then working outwards so that the last de...

Page 5: ...into commission mode and digitally attenuates the receiver signal by 15Db 6 Programming LED s Allows programming of devices directly to the receiver in conjunction with the learn switch Standalone mod...

Page 6: ...ng the expander Connect the expander to the control panel using 4 core cable as follows Expander Control Panel Description 12V Supply 0V Supply T T Transmit Data R R Receive Data The networks are made...

Page 7: ...N A N A N A N A N A N A N A N A N A N A N A Expander Address 1 5 N A N A N A N A N A N A N A N A N A N A N A N A N A N A Premier Elite 168 Exp 1 Exp 2 Exp 1 Exp 2 N A N A N A N A N A N A N A N A N A...

Page 8: ...l dictate which next free zone is chosen to learn too When all device slots have been used the following screen will be shown All Devices Learnt Pressing the N Nkey will return you to the Ricochet lea...

Page 9: ...ce Zone N E n n U N N If all devices are deleted from the system the following will be shown All Devices Deleted Pressing the N Nkey will return you to the Ricochet learn menu pressing the key will en...

Page 10: ...sed on devices which are required to signal at all times and is the default setting for perimeter detection devices such as Contacts and Shock sensors PA Buttons Auto Mode When in Auto Mode devices po...

Page 11: ...the Zone Setup menu please follow the diagram on the next page Zone 00 Panel0 Not sed Yes to Select Zone Setup y Zone 00 P0 0 Not sed R Zone 00 Learn Learning 20s Zone 00 Learn P R P 0 0 y Zone 00 P0...

Page 12: ...tem Free device slots are indicated by the corresponding LED s flashing if the LED s do not flash then that slot is already occupied by another device Depress the Learn switch on the device and insert...

Page 13: ...igures outputs to be momentary When off outputs latch and may be cleared using the Function switch 7 OR 13 Zone 7 SL350 RX Zone 4 PIR 14 Zone 7 SL350 TX Empty 8 OR 15 Zone 8 SL350 RX Zone 4 PIR 16 Zon...

Page 14: ...normally be seen on a recently powered up system wait 15 minutes from power up before checking the diagnostics information Signal Security Zone 00 Shock This display shows information relating to sig...

Page 15: ...ew Event Log YES to Select Engineer tils y U Zone 00 Shock Status aaaSpdtt Zone 00 Shock P Zone 00 Shock P C Zone 00 Not Ricochet C B B ser000 Ricochet Not Ricochet U ser002 Ricochet Not connected Zon...

Page 16: ...nabled when the expander is in tamper When in commission mode the RF signal is attenuated by 6 dB and will reject weak signals This means that when devices are placed into their final locations and co...

Page 17: ...he default setting for the Impaq Contact W and Impaq Plus W For example a Impaq Contact W on a door which you need to know is opened regardless of system state or devices such as PA buttons smoke dete...

Page 18: ...ature 10 C 14 F to 50 C 122 F Storage Temperature 20 C 4 F to 60 C 140 F Maximum Humidity 95 non condensing EMC Environment Residential Commercial Light Industrial or Industrial Physical Dimensions 17...

Page 19: ...Texecom products are designed for reliable trouble free operation Quality is carefully monitored by extensive computerised testing As a result the Premier Elite 32XPH W expander is covered by a two y...

Page 20: ...Lancashire BB4 4PW England Technical Support UK Customers Tel 08456 300 600 Calls charged at local rate from a BT landline Calls from other networks may vary International Customers Tel 44 1706 23387...