
84
9
SCANS
9
■
Programmed scan operation
q
Push
[EXIT/SET]
several times to close a multi-
function screen, if necessary.
w
Select VFO mode.
e
Select the desired operating mode.
• The operating mode can also be changed while scan-
ning.
r
Push
[(F-5)SCAN]
to select the scan screen.
t
Set
[RF/SQL]
open or closed.
• See previous page for scan condition.
• If the
[RF/SQL]
control function is set as “AUTO,” the
squelch is always open in SSB, CW and RTTY modes.
See pgs. 2, 30, 99 for details.
y
Push
[(F-1)PROG]
to start the programmed scan.
• Decimal points blink while scanning.
u
When the scan detects a signal, the scan stops,
pauses or ignores it depending on the resume set-
ting and the squelch condition.
i
To cancel the scan, push
[(F-1)PROG]
.
If the same frequencies are programmed into the
scan edge memory channel P1 and P2, pro-
grammed scan does not start.
SFT
SFT
0
FIL2
FIL2
U S B
U S B
TX
TX
VFO
VFO
USB
USB
USB
USB
USB
USB
FIL2
FIL2
qr.qot.pp
qr.wpt.pp
14.100.00
14.100.00
14.100.00
14.100.00
1
1
VFO
VFO
BW
BW
2.4k
2.4k
SCAN
SCAN
ANT
1
COMP
COMP
OFF
WIDE
WIDE
METER
METER
Po
P.AMP
P.AMP
1
AGC
AGC
MID
MID
ATT
ATT
OFF
OFF
VOX
VOX
OFF
OFF
PROG
PROG
∂
F
FINE
FINE
∂
F SPAN
F SPAN
SET
SET
qw
:
pp
12:00
P R O G R A M S C A N
P R O G R A M S C A N
∂ F S p a n
S p a n
: ±
± 1 0 k H z
1 0 k H z
P r o g r a m m e d
P r o g r a m m e d P 1 :
P 1 :
0 . 5 0 0 . 0 0 M H z
0 . 5 0 0 . 0 0 M H z
s c a n
s c a n e d g e s
e d g e s P 2 :
P 2 : 2 9 . 9 9 9 . 9 9 M H z
2 9 . 9 9 9 . 9 9 M H z
PROG
PROG
∂
F
FINE
FINE
∂
F SPAN
F SPAN
SET
SET
SCAN
SCAN
COMP
COMP
OFF
OFF
WIDE
WIDE
AGC
AGC
MID
MID
VOX
VOX
OFF
OFF
∂ F S p a n
S p a n
: ±
± 1 0 k H z
1 0 k H z
P r o g r a m m e d
P r o g r a m m e d P 1 :
P 1 :
0 . 5 0 0 . 0 0 M H z
0 . 5 0 0 . 0 0 M H z
s c a n
s c a n e d g e s
e d g e s P 2 :
P 2 : 2 9 . 9 9 9 . 9 9 M H z
2 9 . 9 9 9 . 9 9 M H z
■
∂
∂
F scan operation
q
Push
[EXIT/SET]
several times to close a multi-
function screen, if necessary.
w
Select VFO mode or a memory channel.
e
Select the desired operating mode.
• The operating mode can also be changed while scan-
ning.
r
Push
[(F-5)SCAN]
to select the scan screen.
t
Set
[RF/SQL]
open or closed.
• See previous page for scan condition.
• If the
[RF/SQL]
control function is set as “AUTO,” the
squelch is always open in SSB, CW and RTTY modes.
See pgs. 2, 30, 99 for details.
y
Set the
∂
F span by pushing
[(F-4)
∂
∂
F SPAN].
• ±5 kHz, ±10 kHz, ±20 kHz, ±50 kHz, ±100 kHz,
±500 kHz and ±1000 kHz are selectable.
u
Set center frequency of the
∂
F span.
i
Push
[(F-2)
∂
∂
F]
to start the
∂
F scan.
• Decimal points blink while scanning.
o
When the scan detects a signal, the scan stops,
pauses or ignores it depending on the resume set-
ting and the squelch condition.
!0
To cancel the scan, push
[(F-2)
∂
∂
F]
.
SFT
SFT
0
FIL2
FIL2
U S B
U S B
TX
TX
VFO
VFO
USB
USB
USB
USB
USB
USB
FIL2
FIL2
qr.qot.pp
qr.wpt.pp
14.100.00
14.100.00
14.100.00
14.100.00
1
1
VFO
VFO
BW
BW
2.4k
2.4k
SCAN
SCAN
ANT
1
COMP
COMP
OFF
WIDE
WIDE
METER
METER
Po
P.AMP
P.AMP
1
AGC
AGC
MID
MID
ATT
ATT
OFF
OFF
VOX
VOX
OFF
OFF
PROG
PROG
∂
F
FINE
FINE
∂
F SPAN
F SPAN
SET
SET
qw
:
pp
12:00
∂ F S C A N
S C A N
∂ F C e n t e r
C e n t e r
: 1 4 . 1 9 5 . 0 0 M H z
1 4 . 1 9 5 . 0 0 M H z
∂ F S p a n
S p a n
: ±
± 1 0 k H z
1 0 k H z
P r o g r a m m e d
P r o g r a m m e d P 1 :
P 1 :
0 . 5 0 0 . 0 0 M H z
0 . 5 0 0 . 0 0 M H z
s c a n
s c a n e d g e s
e d g e s P 2 :
P 2 : 2 9 . 9 9 9 . 9 9 M H z
2 9 . 9 9 9 . 9 9 M H z
PROG
PROG
∂
F
FINE
FINE
∂
F SPAN
F SPAN
SET
SET
SCAN
SCAN
COMP
COMP
OFF
OFF
WIDE
WIDE
AGC
AGC
MID
MID
VOX
VOX
OFF
OFF
∂ F S p a n
S p a n
: ±
± 1 0 k H z
1 0 k H z
P r o g r a m m e d
P r o g r a m m e d P 1 :
P 1 :
0 . 5 0 0 . 0 0 M H z
0 . 5 0 0 . 0 0 M H z
s c a n
s c a n e d g e s
e d g e s P 2 :
P 2 : 2 9 . 9 9 9 . 9 9 M H z
2 9 . 9 9 9 . 9 9 M H z