44
5
MEMORY AND SCAN OPERATION
➀
Select VFO mode, then set a frequency.
➁
Close the squelch with [SQL].
➂
Set the desired memory channel as the watching
channel.
➃
Select
S2
, then push [
(F-2)
PRI
] to start the watch.
• Decimal point blinks while scanning.
➄
When the scan detects a signal, the scan pauses
for 10 sec. or until the signal disappears, depend-
ing on the resume setting.
➅
To cancel the scan push [
(F-2)
PRI
].
N
No
otte
e::
The paused condition when detecting a signal
differs depending on the scan resume condition.
resume on: pauses for 10 sec.
resume off: pauses until the signal disappears.
➀
Select memory mode.
➁
Close the squelch with [SQL].
➂
Select
S2
, then push [
(F-1)
SCN
] to start the mem-
ory scan.
• Decimal point blinks while scanning.
➃
Push [
(F-2)
SEL
] to change the memory scan to
select memory scan.
• Push [
(F-2)
SEL
] for 2 sec. to clear all select memory
channels.
➄
When the scan detects a signal, the scan stops or
pauses depending on the resume setting.
➅
To cancel the scan push [
(F-1)
SCN
].
N
No
otte
e::
Two or more memory channels must be desig-
nated as select memory channels for select memory
scan to start.
S2 SCN SEL V/M
Select
memory mode
Designate
“S.”
F-1
F-2
Push [
(F-1)
SCN
], then [
(F-2)
SEL
].
CH
S
MEMO
P
O
S1
5
5
3
7
9
20
40
10
60dB
USB
➀
Select memory mode.
➁
Close the squelch with [SQL].
➂
Select
S2
, then push [
(F-1)
SCN
] to start the scan.
• Decimal point blinks while scanning.
➃
When the scan detects a signal, the scan stops or
pauses depending on the resume setting.
➄
To cancel the scan push [
(F-1)
SCN
].
N
No
otte
e::
Two or more memory channels must be pro-
grammed for memory scan to start.
S2 SCN SEL V/M
Select
memory mode
F-1
then push [
(F-1)
SCN
]
CH
MEMO
P
O
S1
5
5
3
7
9
20
40
10
60dB
USB
➀
Select VFO mode.
➁
Select the desired operating mode.
• The operating mode can also be changed while scan-
ning.
➂
Set [SQL] open or closed.
• See page a left for squelch condition.
➃
Select
S2
, then push [
(F-1)
SCN
] to start the scan.
• Decimal point blinks while scanning.
➄
When the scan detects a signal, the scan turns
OFF, pauses or ignores it depending on the
resume setting and the squelch condition.
• During scan [TS] can be used only when resume is ON.
➅
To cancel the scan push [
(F-1)
SCN
].
N
No
otte
e::
If the same frequencies are programmed into
the scan edge memory channels 1A and 1B, pro-
grammed scan does not start.
■
P
Prro
og
grra
am
mm
me
ed
d s
sc
ca
an
n o
op
pe
erra
attiio
on
n
■
M
Me
em
mo
orry
y s
sc
ca
an
n o
op
pe
erra
attiio
on
n
■
S
Se
elle
ec
ctt m
me
em
mo
orry
y s
sc
ca
an
n o
op
pe
erra
attiio
on
n
S2 SCN PRI V/M
Select
VFO mode
Select watching
channel
F-2
Push [
(F-2)
PRI
].
CH
P
O
S1
5
5
3
7
9
20
40
10
60dB
USB
VFO A
■
P
Prriio
orriitty
y w
wa
attc
ch
h
CH
VFO A
P
O
S1
5
5
3
7
9
20
40
10
60dB
USB
S2 SCN PRI V/M
Select
VFO mode
F-1
then push [
(F-1)
SCN
]