APEX 200 USER MANUAL
26
Image data:
{
“timestamp”: “2021.4.9.15:52”, #time stamp
“ip”: “192.168.1.21”, #camera IP
“type”: 0, #data type: 0-image 1-temperature 2-temperature measurement
“resolution”: “1280*720”, #visible light resolution
“resolution”: “1024*768”, #thermal resolution
“formate”: “.jpg”, #image format
“image”: “......” # visible light image data base64 encode
“ir_image”: “......” # thermal image data base64 encode
}
Temperature data:
{
“timestamp”: “2021.4.9.15:52”, # time stamp
“ip”: “192.168.1.21”, #camera IP
“type”: 1, # data type: 0-image 1-temperature 2-temperature measurement
“unit”: “C”, #Unit: ℃
“data”: “......” # temperature data base64 encode
}
Temperature measurement data: temperature measurement function needs to
be enabled in Web
interface.
{
“timestamp”: “2021.4.9.15:52”, # time stamp
“ip”: “192.168.1.21”, # camera IP
“type”: 2, # data type: 0-image 1-temperature 2-temperature measurement
“subnetmask”: “255.255.255.0”, #subnet mask
“gateway”: “192.168.1.1”, #gateway
“mac”: “86:5D:55:0B:A9:74”, #MAC address
“uptime”:33, #boot time
“version”: “V0.2.7”, #software version
“airTemp”: 25, #air temperature(℃)
“airtransmissivit”: 1, #air transmittance