background image

APEX 200 USER MANUAL

36

ICI manufactures complete systems and software. We can provide complete 

engineering, software, and OEM solutions. Our Fortune 500 clients rely on us 

for infrared equipment and thermography training (which we offer through the 

Infrared Training Institute).

In addition to providing custom germanium, silica, and sapphire optics, we also 

build windows for enclosures, as well as custom pan and tilt units. We can even 

provide customizable explosion-proof systems. 

Our  knowledge  and  experience  stems  from  years  of  using  infrared  imaging 

and temperature measurement instruments to provide solutions to: managers, 

engineers,  scientists,  inspectors  and  operators  in  space,  power  companies, 

medical, pulp and paper, food industry, research and development, and various 

process industries. You can see our products and services used in industrial, 

commercial, and government applications worldwide. Additionally, our ICI 7320 

was awarded “Product of the Month” by NASA*. Originally named Texas Infrared 

(still DBA), Infrared Cameras, Inc. has been in business since March, 1995. 

Thank you for your dedicated and continued support.

Infrared Cameras, Inc.

2105 W. Cardinal Dr.

Beaumont, TX 77705

Phone: (409) 861-0788 

Toll Free: (866) 861-0788 

International: (409) 861-0788

Customer Support: [email protected]

Website: www.infraredcameras.com

You may reach a customer care representative by phone or email during regular 

business hours: Monday – Friday 8:00AM - 5:00PM CST.

*Volume 33 No. 2, February 2009 edition of NASA Tech Briefs

13

About ICI

Summary of Contents for APEX 200

Page 1: ...N IMPORTANT SAFETY INFORMATION INSIDE 2105 W Cardinal Dr Beaumont TX 77705 ICI cameras fall under US Federal Law and Export Control For more information contact us 409 861 0788 sales infraredcameras com www infraredcameras com Edit Text Out Ind Industry Revision 05 2022 001 ...

Page 2: ...APEX 200 USER MANUAL 2 Revision History 05 2022 001 Document created ...

Page 3: ...rface 13 5 2 Pin Configuration for Interfaces 14 5 2 1 Ethernet Pin Configuration 8 pin 14 5 2 2 Ethernet Pin Configuration 12 pin 14 Package Includes 15 Quick Start Instructions 16 7 1 Option 1 Rear Housing Installation 16 7 2 Option 2 Front Housing Installation 18 Operation Instructions 20 8 1 Power On Off the Device 20 8 2 Manual IP Address Configuration 21 8 3 Alarms 21 8 3 1 Alarm Input 21 8 ...

Page 4: ...ibration 33 11 4 Storage 33 Troubleshooting 34 12 1 Thermal imager does not power on 34 12 2 Thermal imager shuts off unexpectedly 34 12 3 No thermal image 34 12 4 Unclear or dark visible images 34 12 5 Image is stuck 34 12 6 Cannot log into software 34 12 7 Temperature readings are incorrect 35 About ICI 36 12 13 ...

Page 5: ...rmission of Infrared Cameras Inc The documentation must not in whole or part be copied photocopied reproduced translated or transmitted to any electronic medium or machine readable form without prior consent in writing from Infrared Cameras Inc Names and marks appearing on the products herein are either registered trademarks or trademarks of Infrared Cameras Inc and or its subsidiaries All other t...

Page 6: ...e crossed out wheeled bin symbol indicates that waste electrical and electronic equipment should not be discarded together with unseparated household waste but must be collected separately All local authorities have established collection schemes under which residents can dispose of equipment at a recycling center or other collection points or WEEE will be collected directly from households More d...

Page 7: ... first 1 1000th of an inch of a subject Environment of use industrial and petrochemical buildings electrical plants security rooms science labs animal reserves as well as environmental conservatories and aerial integrations among others You agree that this product is for civilian use only and shall not use applications that may infringe the rights of third parties medical and safety devices or oth...

Page 8: ...APEX 200 USER MANUAL 8 2 9 Training To read about infrared training visit https infraredtraininginstitute com ...

Page 9: ...ge the battery if it does not become charged in the specified charging time If you continue to charge the battery it can become hot and cause an explosion or ignition Injury to persons can occur Do not attach the batteries directly to a car s cigarette lighter socket Using the incorrect equipment can cause the battery to become hot or cause an explosion Only use the correct equipment to discharge ...

Page 10: ... local state and federal regulations Do not use the battery if when used charged or placed in storage there is an unusual smell from the battery the battery feels hot changes color changes shape or is in an unusual condition Speak with a sales office if one or more of these problems occurs Clean the case with a damp cloth and a weak soap solution Do not use abrasives isopropyl alcohol or solvents ...

Page 11: ...ions without lens 109 mm x 55 9 mm x 29 5 mm L x W x D 0 5 mm 4 29 x 2 20 x 1 16 L x W x H 0 02 Power DC 12V to 24V 2W PoE support Weight 170 g 6 oz Interface 8 pin M12 A type connector including 10M 100M adaptive RJ 45 Ethernet port and POE power supply 12 pin M12 A type connector including DC power supply alarm input and output Protocols Network TCP UDP RTSP HTTP SMTP Interface ONVIF GB28181 Mod...

Page 12: ...support Internal non uniformity correction NUC Remote reset and device reset button Specifications subject to change without further notice Models and accessories subject to regional market considerations License procedures may apply Products described herein may be subject to US Export Regulations Please refer to support infraredcameras com with any questions ...

Page 13: ...f Interface 1 Illuminator 2 Visible Camera 3 Germanium Lens 4 8 Pin M12 Connector Ethernet and PoE cable interface 5 12 Pin M12 Connector DC Power supply and alarm input output 6 Power Indicator 7 Network Indicator 8 Reset Button 5 Structure 1 2 3 4 5 6 7 8 ...

Page 14: ...Pin Configuration 12 pin 1 2 3 9 10 11 12 8 4 5 6 7 1 2 3 4 5 6 7 8 Pin Configuration Pin Configuration 1 TX 5 PD 2 TX 6 PD 3 RX 7 PD 4 RX 8 PD Pin Configuration Pin Configuration 1 Power 7 ALARM_POWER2 2 Power 8 ALARM_OUT2 3 Power Ground 9 ALARM_IN 4 Power Ground 10 ALARM_IN 5 ALARM_POWER1 11 NC 6 ALARM_OUT1 12 NC ...

Page 15: ...USER MANUAL 15 6 Package Includes ENSURE ALL SYSTEM EQUIPMENT AND COMPONENT ITEMS ARE PRESENT BEFORE BEGINNING INSTALLATION APEX 200 M2 Screws x8 Ethernet Data Cable ST2 2 Screws x8 PoE Injector Alignment Guides ...

Page 16: ...LES FOR SETTING DEVICE SCREWS THE THERMAL DEVICE WILL ACCUMULATE HEAT DURING OPERATION ICI RECOMMENDS MOUNTING THE THERMAL DEVICE TO METALLIC OBJECTS AT ITS REAR HOUSING WHICH CAN REDUCE DEVICE HEATING AS WELL AS DECREASE THE TEMPERATURE DRIFT OF THE DETECTOR DO NOT USE TOO LONG SCREWS WHEN INSTALLING THE FRONT REAR MOUNTING BRACKET USING SCREWS THAT ARE TOO LONG MAY DAMAGE THE THERMAL CAMERA THE ...

Page 17: ...VICE WITHOUT ALIGNING THE PINS FORCING THE CABLE ONTO THE DEVICE MAY RESULT IN DAMAGE TO THE PINS ALTERNATIVELY POWER CAN BE PROVIDED THROUGH THE 12 PIN CONNECTOR VIA A POWER ADAPTER NOT PROVIDED Plug the PoE injector into a 110 120V electrical outlet Plug the Ethernet end of the Ethernet data cable into the PoE injector THE THERMAL IMAGER NEEDS SUFFICIENT WARM UP TIME FOR THE MOST ACCURATE TEMPER...

Page 18: ...FOR SETTING DEVICE SCREWS THE MAXIMUM HOLE DEPTH OF THE FRONT SHELL IS 10 MM 0 4 IN AND THE MAXIMUM HOLE DEPTH OF THE REAR SHELL IS 4 MM 0 16 IN THE THERMAL DEVICE WILL ACCUMULATE HEAT DURING OPERATION ICI RECOMMENDS MOUNTING THE THERMAL DEVICE TO METALLIC OBJECTS AT ITS REAR HOUSING WHICH CAN REDUCE DEVICE HEATING AS WELL AS DECREASE THE TEMPERATURE DRIFT OF THE DETECTOR DO NOT USE TOO LONG SCREW...

Page 19: ...VICE WITHOUT ALIGNING THE PINS FORCING THE CABLE ONTO THE DEVICE MAY RESULT IN DAMAGE TO THE PINS ALTERNATIVELY POWER CAN BE PROVIDED THROUGH THE 12 PIN CONNECTOR VIA A POWER ADAPTER NOT PROVIDED Plug the PoE injector into a 110 120V electrical outlet Plug the Ethernet end of the Ethernet data cable into the PoE injector THE THERMAL IMAGER NEEDS SUFFICIENT WARM UP TIME FOR THE MOST ACCURATE TEMPER...

Page 20: ...E port of the power supply through the M12 8 pin adapter cable or Connect to the DC power supply through the M12 12 pin adapter cable 2 Connect the APEX 200 to the network 3 Power on the device and wait for 2 minutes The power indicator light is steady blue when fully powered The network indicator light flashes green when the network connection is normal 4 Modify the computer network segment to be...

Page 21: ...Click Change Adapter Settings 6 Right click Ethernet and choose properties For touchscreens press and hold until a box pops up then release hold 7 Double click on Internet Protocol Version 4 TCP IPV4 Properties 8 The IP address should read 192 168 1 110 If it does not click in the box and fill in the correct number 9 The Subnet Mask should read 255 255 255 0 If it does not click in the box and fil...

Page 22: ...allation ICI s VMS software is provided as a download Customer service can be contacted for a downloadable copy 1 Download the file provided by customer support and follow your browser s instructions for saving files 2 Open the file save location 3 Double click the APEX 200_VMS_AT20_V105 exe file 4 Grant system permission Click Yes if you agree to continue software installation Click No to abort i...

Page 23: ...e software installation Click Back to go to the previous step Click Cancel to stop installation 10 Click Install to continue software installation Click Back to go to the previous step Click Cancel to stop installation 11 Wait while software install ...

Page 24: ...2 Click Apps 12 Click Finish to close the setup wizard 3 Find IRT_VMS in the list and click it 4 Click Uninstall 5 Click Uninstall to confirm removal Click Cancel to stop removal 6 Grant system permission Click Yes if you agree to uninstall the software Click No to cancel process 7 Click OK IRT_VMS ...

Page 25: ...own on next pages 10 Protocols IP Camera IP default 192 168 1 20 Port 1502 Register Address R W Length word Data 0x0001 R 2 Version No e g 0x0102 0x0304 V1 2 3 4 0x0003 R 1 0x0004 R 1 0x0005 R 1 0x0006 R 1 0x0007 R 2 The highest temperature of the entire frame The actual temperature register value 2732 10 0 0x0009 R 2 The average temperature of the entire frame 0x000B R 2 The lowest temperature of...

Page 26: ...15 52 time stamp ip 192 168 1 21 camera IP type 1 data type 0 image 1 temperature 2 temperature measurement unit C Unit data temperature data base64 encode Temperature measurement data temperature measurement function needs to be enabled in Web interface timestamp 2021 4 9 15 52 time stamp ip 192 168 1 21 camera IP type 2 data type 0 image 1 temperature 2 temperature measurement subnetmask 255 255...

Page 27: ...ature measurement area enable 1 is valid index 0 temperature index enable 1 enable temperature measuring or not type 0 type 0 rectangle 1 line 2 point x0 67 start x value y0 61 start y value x1 125 end x value y1 98 end y value maxTemp 45 5 maximum temperature of the region minTemp 45 minimum temperature of the region avgTemp 45 3 average temperature of the region index 1 enable 0 type 0 x0 0 y0 0...

Page 28: ...AL 28 x0 0 y0 0 x1 0 y1 0 maxTemp 0 minTemp 0 avgTemp 0 index 3 enable 0 type 0 x0 0 y0 0 x1 0 y1 0 maxTemp 0 minTemp 0 avgTemp 0 index 4 enable 0 type 0 x0 0 y0 0 x1 0 y1 0 maxTemp 0 minTemp 0 avgTemp 0 index 5 enable 0 ...

Page 29: ...UAL 29 type 0 x0 0 y0 0 x1 0 y1 0 maxTemp 0 minTemp 0 avgTemp 0 index 6 enable 0 type 0 x0 0 y0 0 x1 0 y1 0 maxTemp 0 minTemp 0 avgTemp 0 index 7 enable 0 type 0 x0 0 y0 0 x1 0 y1 0 maxTemp 0 minTemp 0 avgTemp 0 index 8 ...

Page 30: ...AL 30 enable 0 type 0 x0 0 y0 0 x1 0 y1 0 maxTemp 0 minTemp 0 avgTemp 0 index 9 enable 0 type 0 x0 0 y0 0 x1 0 y1 0 maxTemp 0 minTemp 0 avgTemp 0 index 10 enable 0 type 0 x0 0 y0 0 x1 0 y1 0 maxTemp 0 minTemp 0 avgTemp 0 ...

Page 31: ... index 11 enable 0 type 0 x0 0 y0 0 x1 0 y1 0 maxTemp 0 minTemp 0 avgTemp 0 index 12 enable 0 type 0 x0 0 y0 0 x1 0 y1 0 maxTemp 0 minTemp 0 avgTemp 0 index 13 enable 0 type 0 x0 0 y0 0 x1 0 y1 0 maxTemp 0 minTemp 0 avgTemp 0 ...

Page 32: ...APEX 200 USER MANUAL 32 index 14 enable 0 type 0 x0 0 y0 0 x1 0 y1 0 maxTemp 0 minTemp 0 avgTemp 0 index 15 enable 0 type 0 x0 0 y0 0 x1 0 y1 0 maxTemp 0 minTemp 0 avgTemp 0 ...

Page 33: ...ace the cloth and repeat the wiping process 11 2 Disinfecting the Camera Surface Do not use corrosive cleaning solutions on the optical glass components It is recommended to disinfect the camera surface regularly with a non corrosive sanitizing product Follow the directions provided by the manufacturer of the cleaning solution Adhere to the sanitation protocols and cleaning schedule set forth by t...

Page 34: ... 24V 12 Troubleshooting 12 2 Thermal imager shuts off unexpectedly Ensure cables are connected properly 12 3 No thermal image Ensure cables are connected properly If lens is foggy use professional equipment to clean the lens 12 5 Image is stuck Ensure cables are connected properly Restart the software 12 4 Unclear or dark visible images If lens is foggy use professional equipment to clean the lens...

Page 35: ...mperature measurement Ensure the correct temperature range is selected The default temperature range is 40 C to 150 C 40 F to 302 F When measuring high temperature objects ensure the temperature range is set to the 100 C to 800 C 212 F to 1472 F range Device is at proper height Ensure device is in focus Adjust emissivity Adjust for ambient temperature Wait for or perform a manual NUC operation Sen...

Page 36: ...d operators in space power companies medical pulp and paper food industry research and development and various process industries You can see our products and services used in industrial commercial and government applications worldwide Additionally our ICI 7320 was awarded Product of the Month by NASA Originally named Texas Infrared still DBA Infrared Cameras Inc has been in business since March 1...

Reviews: