-27-
iCharger Synchronous Balance Charger/Discharger 208B
General Status information
General Status Information
Voltage of Balance Port
Warning and error in formation
The
iCharger
incorporates a wide range of protection and alarm functions to monitor the operation of the
charger. This includes verifying the internal state and the condition of its electronics. In the case of any error
being detected the screen displays the error cause and the charger generates 3 beeps. If the error occurs
during a charging, discharging or cycling process the error message and termination data will appear
alternately.
When an error has been reported press
Batt type/Stop
to return to the
main menu. Press
Inc
or
Dec
to check the parameter value related to
the error. For example in the case of a temperature error you can check the
temperature that triggered the error.
Press
Start/Enter
to return to the error
message screen. Expression ―-‖ refers to the discharged capacity to packs
Termination at
-01245mAh 01h:32
Termination
time
Termination
power
Inc
CHG 1 00213mAh
DCHG 1 00199mAh
CHG 2 00203mAh
DCHG 2 00197mAh
Inc
。
。
。
Cycle Information
Note:
Toggle back to the last
viewed parameter via the
Dec
button, press
Dec
again to
move to the next parameter.
Inc
1:4.01 4.03 4.07
4:4.02 4.05 4.04
Inc
7:4.01 4.03
End Voltage
16.80V
Input power 3A
Voltage 11.80V
Ext.Temp 30℃
Int.Temp 40℃
Capacity Cut-Off
ON 5000mAh
Safety timer
ON 120min
Temp Cut-Off
OFF 50℃
Dec
Dec
Dec
Dec
Dec
Dec
Start/Enter
>3 seconds
Change the
value
Start/Enter
>3 seconds
Change the
value
Start/Enter
>3 seconds
Change the
value
Summary of Contents for 208B